DC & AC Contactors
Modular Contactor |

Household AC Contactor |
-
Household AC contactor is mainly used in the circuit of AC 50 (60) HZ, rated voltage is up to 230V, and rated current is up to 25A, and it is to control the low-induction and micro-induction load of household electrical appliances or etc. It also can be used to control the household motor load (on this occasion, the control power should be low correspondingly.
GMC Contactor |
![]() |
![]() |
![]() |
|
GMC9-22 |
GMC32-40 |
GMC50-85 |
GMC100-125 |
Specification
Model |
GMC-9 |
GMC-12 |
GMC-18 |
GMC-22 |
GMC-32 |
GMC-40 |
||
| IEC-60947 AC1 duty | 20A |
20A |
25A |
32A |
50A |
60A |
||
| UL AC3 duty | 200-240V | 2.5KW 11A |
3.5KW 13A |
4.5KW 18A |
5.5KW 22A |
7.5KW 32A |
11KW 40A |
|
| 380-440V | 4KW 9A |
5.5KW 12A |
7.5KW 18A |
11KW 22A |
15KW 32A |
18.5KW 40A |
||
| 500-550V | 4KW 7A |
7.5KW 12A |
7.5KW 13A |
15KW 22A |
18.5KW 28A |
22KW 32A |
||
| 690V | 4KW 5A |
7.5KW 9A |
7.5KW 9A |
15KW 18A |
18.5KW 21A |
22KW 25A |
||
| Continuous current(th) | 20A |
25A |
30A |
32A |
45A |
50A |
||
| AC Motor | 1P | 115V | 0.5HP |
0.5HP |
1HP |
2HP |
2HP |
3HP |
| 230V | 1HP |
2HP |
3HP |
3HP |
5HP |
5HP |
||
| 3P | 200V | 2HP |
3HP |
5HP |
7HP |
7.5HP |
10HP |
|
| 230V | 2HP |
3HP |
5HP |
7.5HP |
10HP |
10HP |
||
| 460V | 5HP |
7.5HP |
10HP |
10HP |
20HP |
25HP |
||
| 575V | 7.5HP |
10HP |
15HP |
15HP |
20HP |
25HP |
||
| Panel installation | Rail & screw |
|||||||
| External dimension(mm) | 44x80x86.8 |
68x82x94.6 |
||||||
| Mounting dimension(mm) | 30~35x48~59 |
|||||||
Model |
GMC-50 |
GMC-65 |
GMC-75 |
GMC-85 |
GMC-100 |
GMC-125 |
||
| IEC-60947 AC1 duty | 80A |
100A |
110A |
135A |
150A |
150A |
||
| UL AC3 duty | 200-240V | 15KW 55A |
18.5KW 65A |
22KW 75A |
25KW 85A |
30KW 105A |
37KW 125A |
|
| 380-440V | 22KW 50A |
30KW 65A |
37KW 75A |
45KW 85A |
55KW 105A |
60KW 120A |
||
| 500-550V | 30KW 43A |
37KW 60A |
45KW 64A |
45KW 75A |
55KW 85A |
60KW 90A |
||
| 690V | 30KW 33A |
37KW 47A |
45KW 47A |
45KW 52A |
55KW 65A |
60KW 70A |
||
| Continuous current(th) | 70A |
80A |
90A |
100A |
160A |
160A |
||
| AC Motor | 1P | 115V | 3HP |
5HP |
5HP |
7.5HP |
7.5HP |
10HP |
| 230V | 7.5HP |
10HP |
15HP |
15HP |
15HP |
20HP |
||
| 3P | 200V | 10HP |
15HP |
20HP |
25HP |
30HP |
40HP |
|
| 230V | 15HP |
20HP |
25HP |
30HP |
30HP |
40HP |
||
| 460V | 30HP |
40HP |
50HP |
50HP |
60HP |
75HP |
||
| 575V | 30HP |
40HP |
50HP |
50HP |
60HP |
75HP |
||
| Panel installation | Rail & screw |
|||||||
| External dimension(mm) | 94x123.5x117.4 |
100x157.4x146.5 |
||||||
| Mounting dimension(mm) | 100x50~60 |
80x110 90x125 |
80x100 90x125 |
|||||
3TB Series AC Contactor |
Application
The contactor is suitable for using in the circuit up to the rated voltage 660V AC 50Hz or 60Hz, rated current 630A, for making and breaking, and for frequent starting and controlling the motor.After combined with the mechanical interlocking device, it becomes 3TD Series convertible contactor for Controlling, starting, breaking and Reversing of the motor. The products comply with IEC947 & VDE0660.
![]() |
![]() |
![]() |
![]() |
3TB41 |
3TB42 |
3TB43 |
3TB44 |
Specifications
Type |
Rated thermal current (A) |
Rated operating current at 380V(A) |
Rated operating current at 660V(A) |
The power of controlled motor (KW) |
Type of auxiliary contact |
||
380(V) |
660(V) |
1NO 1NC 1NO+1NC 2NO+2NC |
|||||
3TB40 |
22 |
9 |
7.2 |
4 |
5.5 |
||
3TB41 |
22 |
12 |
9.5 |
5.5 |
7.5 |
||
3TB42 |
35 |
16 |
13.5 |
7.5 |
11 |
||
3TB43 |
35 |
22 |
13.5 |
11 |
11 |
||
3TB44 |
55 |
32 |
18 |
15 |
15 |
2NO+2NC |
|
3TH Contactor |
Application
The auxiliary contactors is the auxiliary suited by controlled circuit with voltage is AC 50/60Hz,660V and DC 660V.They control all kinds of magnetic coil and amplify or transfer signal to relative controlled element simultaneously.They are characterized by high performance & long service life
![]() |
![]() |
![]() |
![]() |
3TH30 |
3TH40 |
3TH42 |
3TH80 |
Specifications
Rated Voltage |
Rated operational current(A) |
Controllable motor power AC3(KW) |
||
le=AC11、AC14 |
DC11 |
|||
110V |
- |
0.9 |
- |
|
220V |
10 |
0.45 |
2.2 |
|
380V |
6 |
- |
4 |
|
440V |
- |
0.25 |
4 |
|
660V |
2 |
- |
4 |
|
Type |
Type of contact |
|
NO |
NC |
|
3TH30 |
4 |
1 |
31-OA |
3 |
2 |
22-OA |
2 |
3 |
13-OA |
1 |
4 |
04-OA |
- |
- |
3TH40/3TH80 40-OA |
4 |
1 |
31-OA |
3 |
2 |
22-OA |
2 |
3 |
13-OA |
1 |
4 |
04-OA |
- |
- |
3TH42/3TH82 80-OA |
8 |
- |
71-OA |
7 |
1 |
62-OA |
5 |
2 |
53-OA |
5 |
4 |
44-OA |
4 |
- |
3TF Contactor |
Application
3TF series AC contactors are suitable in electrical system with AC 50/60HZ, rated operational voltage up to 660V, in AC-3 usage, rated operational voltage up to 380V, rated operational current up to 630A to make or break remote motors or system. They can form electromagnetic starters with suitable thermal overload relays 3UA series to protect system and motors against overload or phase-failure. They are made according to IEC947-2, BS5424 & VDE0660.
The contactor is a straight motion mechanism having double-breaking contacts. The auxiliary contacts are arranged 2NO, 2NC at most. It is employed the flexible locking connection between the contact support and core. There are no arc-isolated panel in the le≤22A contactors. In the In≥32A contactors, there are moulded arc-chute with arc-isolated panel. Because all contacts are made of high non-fusibility and against corrosion silver alloy. All series products can be mounted by screws, le≤32A contactor also by installation rail.
![]() |
![]() |
![]() |
3TF-40 |
3TF-47 |
3TF-53 |
Specification
Type |
Rated thermal current(A) |
Rated operation current(A) |
Controllable power of motor(KW) |
Type of auxliliary contact |
||||
AC-3 |
AC-4 |
|||||||
380V |
660V |
380V |
660V |
380V |
660V |
|||
3TF30 |
20 |
9 |
7 |
4 |
5.5 |
1.4 |
2.4 |
NO NC 1NO+1NC 2NO+2NC |
3TF31 |
20 |
12 |
7.5 |
5.5 |
7.5 |
1.9 |
3.3 |
|
3TF32 |
30 |
16 |
12.5 |
7.5 |
11 |
3.5 |
6 |
|
3TF33 |
30 |
22 |
16.5 |
10 |
15 |
4 |
6.6 |
|
3TF34 |
55 |
32 |
24 |
15 |
22 |
7.5 |
13 |
|
3TF35 |
55 |
38 |
24 |
18.5 |
22 |
9 |
15.5 |
|
3TF40 |
20 |
9 |
7 |
4 |
5.5 |
1.4 |
2.4 |
|
3TF41 |
20 |
12 |
7.5 |
5.5 |
7.5 |
1.9 |
3.3 |
|
3TF42 |
30 |
16 |
12.5 |
7.5 |
11 |
3.5 |
6 |
|
3TF43 |
30 |
22 |
16.5 |
10 |
15 |
4 |
6.6 |
|
3TF44 |
55 |
32 |
24 |
15 |
22 |
7.5 |
13 |
|
3TF45 |
55 |
38 |
24 |
18.5 |
22 |
9 |
15.5 |
|
3TF46 |
80 |
45 |
40 |
22 |
37 |
12 |
20.8 |
2NC+2NO 4NC+4NO |
3TF47 |
80 |
63 |
60 |
30 |
55 |
14 |
24.3 |
|
3TF48 |
100 |
75 |
60 |
37 |
55 |
17 |
29.5 |
|
3TF49 |
100 |
85 |
80 |
45 |
75 |
21 |
36 |
|
3TF50 |
160 |
110 |
95 |
55 |
90 |
27 |
46.9 |
|
3TF51 |
160 |
140 |
120 |
75 |
110 |
35 |
60 |
|
3TF52 |
200 |
170 |
160 |
90 |
150 |
38 |
66 |
|
3TF53 |
210 |
205 |
165 |
110 |
160 |
50 |
86 |
|
3TF54 |
300 |
250 |
230 |
132 |
220 |
58 |
100 |
|
3TF55 |
300 |
300 |
260 |
160 |
250 |
66 |
114 |
|
3TF56 |
400 |
400 |
380 |
200 |
355 |
81 |
140 |
|
3TF68 |
630 |
630 |
600 |
335 |
560 |
160 |
278 |
|
3TD Contactor |
Application
The contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz-60Hz, current 300A, for convertible controlling the motor. Its mechanical interlocking device ensures contact changeover of the two convertible contactors.
![]() 3TD32 3TD33 |
![]() 3TD54 3TD55 |
Specificatons
Type |
Rated thermal current(A) |
Reted operation current(A) |
Controllable power of motor(KW) |
||||
AC-3 |
AC-4 |
||||||
380V |
660V |
380V |
660V |
380V |
660V |
||
3TD40 |
20 |
9 |
7 |
4 |
5.5 |
1.4 |
2.4 |
3TD41 |
20 |
12 |
8.5 |
5.5 |
7.5 |
1.9 |
3.3 |
3TD42 |
30 |
16 |
12.5 |
7.5 |
11 |
3.5 |
6 |
3TD43 |
30 |
22 |
16.5 |
10 |
15 |
4 |
6.6 |
3TD44 |
55 |
32 |
24 |
15 |
22 |
7.5 |
13 |
3TD45 |
55 |
38 |
24 |
18.5 |
22 |
9 |
15.5 |
3TD46 |
80 |
45 |
40 |
22 |
37 |
12 |
20.8 |
3TD47 |
80 |
63 |
60 |
30 |
55 |
14 |
24.3 |
3TD48 |
100 |
75 |
60 |
37 |
55 |
17 |
29.5 |
3TD49 |
100 |
85 |
80 |
45 |
75 |
21 |
36 |
3TD50 |
160 |
110 |
95 |
55 |
90 |
27 |
46.9 |
3TD51 |
160 |
140 |
120 |
75 |
110 |
35 |
60 |
3TD52 |
200 |
170 |
160 |
90 |
150 |
38 |
66 |
3TD53 |
210 |
205 |
165 |
110 |
160 |
50 |
86 |
3TD54 |
300 |
250 |
230 |
132 |
220 |
58 |
100 |
3TD55 |
300 |
300 |
230 |
160 |
250 |
66 |
114 |
LC1-K & LC1-E Contactor |
Application
LC1-K Series AC cortactor is suitable for use in the circuit up to the rate and frequent starting, controlling the AC motor. The addtion of auxiliary contact group to the contactor, combined with the proper thermal relay, can act to protect the circuit bound to overload.
![]() |
![]() |
LC1-K06, 09, 12 |
LC1-K06, 09, 12 |
Specification
Type |
Rated working current A (380V) |
AC-3 use group control power KW |
Contact data(1) |
|||
220V |
380/415V |
440/500V |
660V |
|||
LC1-K06 |
6 |
1.5 |
2.2 |
3 |
3 |
3P+NC 3P+NO |
LC1-K09 |
9 |
2.2 |
4 |
4 |
4 |
3P+NC 3P+NO |
LC1-K12 |
12 |
3 |
3 |
5 |
5 |
3P+NC 3P+NO |
| Specifications | LC1-K06 |
LC1-K09 |
LC1-K12 |
||
| Use group under AC-3 | 6 |
9 |
12 |
||
| Rated working current (le)A | 5 |
7.5 |
10 |
||
| Conventional thermal current(Ith)A | 16 |
20 |
20 |
||
| Rated working voltage(Ue)V | 380 660 |
||||
| Rated insullation voltage (Ui)V | 690 |
||||
| AC-3 (6Ie Ie) | Electrical life (time) | 0.5x 106 |
|||
| Operation frequency h-1 | 1200 |
||||
| AC-3 (6Ie Ie) | Electrical life (time) | 10x104 |
|||
| Operation frequency h-1 | 300 |
||||
| Mecnical life | 3x106 |
||||
| Auxiliary contact | Conventional thermal current | 6A |
|||
| Electrical life (time) | AC-15(360VA) | 0.5x106 |
|||
| DC-13(33W) | |||||
| Coil specifications | Rated control voltage (Us) | AC: 12, 24, 45, 110, 220, 380 DC: 12, 24, 45, 110, 220 |
|||
| Pick-up voltage | AC: 0.85~1.1Us DC: 0.85~1.1Us |
||||
| Resleasing voltage | AC: 0.1~0.75Us DC: 0.2~0.75Us |
||||
| Coil power VA | Pick-up | 40 |
|||
| Fotain | 4 |
||||
| Consumption | 1.2W |
||||
| Pick-up time | 6~18ms |
||||
| Releasing time | 5~23ms |
||||
| Power factor | Making 0.8 Breaking 0.3 |
||||
CJX2(LC1-D OLD TYPE)Contactor |
1.Application
CJX2(LC1-D) series AC Contactor is suitable for using in the circuits up to the rated voltage 660V AC50Hz or 60Hz, rated current up to 620A, for making, breaking, frequently starting & controllingthe AC motor. Combined with the auxiliary contact block, timer delay & machine-interlockingdevice etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.With the thermal relay, it is combined into the electromagnetic starter. The product conforms toIEC60947-4-1 stardand.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Type | CJX2-D09 | CJX2-D12 | CJX2-D18 | CJX2-D25 | CJX2-D32 | CJX2-D40 | CJX2-D50 | CJX2-D65 | CJX2-D80 | CJX2-D95 | |
| Rated workingcurrent (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
| AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
| Standardpower ratingsof 3-phase motors 50/60Hz incategory AC-3 | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
| 380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
| 415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 | |
| 500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | 55 | 55 | |
| 660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 55 | |
| Rated heat current (A) | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 125 | 125 | |
| Electrical life | AC3 (x104) | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
| AC4 (x104) | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 | |
| Mechanical life (x104) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 | |
| Number of the contacts | 3P+NO | 3P+NC+NO | |||||||||
| 3P+NC | |||||||||||
| Type | CJX2-D115 | CJX2-D150 | CJX2-D170 | CJX2-D205 | CJX2-D245 | CJX2-D300 | CJX2-D410 | CJX2-D475 | CJX2-D620 | |
| Rated workingcurrent (A) | AC3 | 115 | 150 | 170 | 205 | 245 | 300 | 410 | 475 | 620 |
| AC4 | 52 | 60 | 75 | 85 | 105 | 117 | 138 | 147 | 180 | |
| Standard powerratings of 3-phase motors 50/60Hz incategory AC-3 | 220/230V | 30 | 40 | 55 | 63 | 75 | 100 | 110 | 147 | 200 |
| 380/400V | 55 | 75 | 90 | 110 | 132 | 160 | 220 | 265 | 335 | |
| 415V | 59 | 80 | 100 | 110 | 132 | 180 | 220 | 280 | 375 | |
| 500V | 75 | 90 | 110 | 129 | 160 | 200 | 250 | 355 | 400 | |
| 660/690V | 80 | 100 | 110 | 129 | 160 | 220 | 280 | 355 | 450 | |
| Rated heat current (A) | 200 | 250 | 250 | 275 | 315 | 400 | 500 | 700 | 1000 | |
| Electrical life | AC3 (x104) | 200 | 60 | 60 | 50 | 50 | 50 | 30 | 30 | 20 |
| AC4 (x104) | 15 | 15 | 15 | 15 | 15 | 15 | 8 | 8 | 5 | |
| Mechanical life (x104) | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 100 | 100 | 100 |
3. Standard Control Circuit Voltage
| Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 600 |
| 50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 |
| 60Hz | B6 | D6 | E6 | F6 | M6 | - | U6 | Q6 | - | - | R6 | - | - |
| 50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 | - | - |
4. Outline and Mounting Dimension

| Type | A | B | C | D | E | a | b | Φ |
| CJX2-D09~12 | 47 | 76 | 82 | 113 | 133 | 34/35 | 50/60 | 4.5 |
| CJX2-D18 | 47 | 76 | 87 | 118 | 138 | 34/35 | 50/60 | 4.5 |
| CJX2-D25 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 4.5 |
| CJX2-D32 | 57 | 86 | 100 | 131 | 151 | 40 | 48 | 4.5 |
| CJX2-D40~65 | 77 | 129 | 116 | 145 | 165 | 40 | 100/110 | 6.5 |
| CJX2-D80~95 | 87 | 129 | 127 | 175 | 195 | 40 | 100/110 | 6.5 |

| Type | A | B | C | b1 | P | Q | S | Q1 | M | N | L | Φ | Ga | Ha |
| CJX2-D115 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
| CJX2-D150 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
| CJX2-D170 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
| CJX2-D205 | 168.5 | 174 | 181 | 137 | 40 | 69 | 20 | 59.4 | 154 | 127 | 113.5 | M8 | 80 | 120-106 |
| CJX2-D245 | 168.5 | 197 | 181 | 137 | 48 | 69 | 25 | 51.5 | 172 | 127 | 113.5 | M10 | 80 | 120-106 |
| CJX2-D300 | 213 | 206 | 219 | 145 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
| CJX2-D410 | 213 | 206 | 219 | 209 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
| CJX2-D475 | 233 | 238 | 232 | 209 | 55 | 108 | 30 | 77 | 208 | 172 | 146 | M10 | 80 | 180 |
| CJX2-D620 | 309 | 304 | 255 | 280 | 80 | 140 | 40 | 89 | 264 | 202 | 155 | M12 | 80 | 180 |
5. Auxiliary contact block
| Appellation | Type | |
| Auxiliary instantaneous contactor block,contactor I |
LA1-DN10C | ![]() |
| LA1-DN01C |
| Appellation | Type | |
| Auxiliary instantaneous contactor block,contactor II |
LA1-DN11C | ![]() |
| LA1-DN20C | ||
| LA1-DN02C |
| Appellation | Type | |
| Auxiliary instantaneous contactor block,contactor IV |
LA1-DN40C | ![]() |
| LA1-DN31C | ||
| LA1-DN22C | ||
| LA1-DN13C | ||
| LA1-DN04C |
| Appellation | Type | |
| Auxiliary instantaneous contactor block,contactor IV |
LA1-DN40C | ![]() |
| LA1-DN31C | ||
| LA1-DN22C | ||
| LA1-DN13C | ||
| LA1-DN04C |
| Appellation | Type | |
| Side-mounted auxiliary module | LA8-DN11C | ![]() |
| LA8-DN20C |
6. LA2 time delay auxiliary contact block
| Appellation | Type | |
| Auxiliary instantaneouscontactor block,contactor IV | 0.1...3S LA2-DT0 | ![]() |
| 0.1...30S LA2-DT2 | ||
| 10...180S LA2-DT4 | ||
| 1...30S LA2-DS2 |
| Appellation | Type | |
| Time delay auxiliary contactorblock releasing and delay | 0.1...3S LA2-DT0 | ![]() |
| 0.1...30S LA3-DT2 | ||
| 10...180S LA3-DT4 |
| Contactor | Auxiliary Blocks | Relative products | ||||
![]() |
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
LC1-D(New type) Contactors |
|
![]() |
![]() |
|
LC1-D12
|
LC1-D65 |
LC1-D95 |
LC1-D150
|
Specification
Model |
LC1-D09 |
LC1-D12 |
LC1-D18 |
LC1-D25 |
LC1-D32 |
LC1-D40 |
|
Rated operational current |
Ie max AC-3 |
9A |
12A |
18A |
25A |
32A |
40A |
Ie AC-1 |
25A |
32A |
40A |
50A |
60A |
||
Rated operational voltage |
690V |
||||||
Pole No. |
3P |
3P,4P |
3P |
3P,4P |
3P |
3P,4P |
|
Rated operational power in AC-3 |
220/240V |
2.2KW |
3KW |
4KW |
5.5KW |
7.5KW |
11KW |
380/400V |
4KW |
5.5KW |
7.5KW |
11KW |
15KW |
18.5KW |
|
415/440V |
4KW |
5.5KW |
9KW |
11KW |
15KW |
22KW |
|
500V |
5.5KW |
7.5KW |
10KW |
15KW |
18.5KW |
22KW |
|
660/690V |
5.5KW |
7.5KW |
10KW |
15KW |
18.5KW |
30KW |
|
1000V |
- |
- |
- |
- |
- |
22KW |
|
Thermal overload relays |
class 10A |
0.10...10A |
0.10...13A |
0.10...18A |
0.10...32A |
0.10...38A |
17...50A |
class 20 |
2.5...10A |
2.5...13A |
2.5...18A |
2.5...32A |
- |
17...40A |
|
Model |
LC1-D50 |
LC1-D65 |
LC1-D80 |
LC1-D95 |
LC1-D115 |
LC1-D150 |
|
Rated operational current |
Ie max AC-3 |
50A | 65A | 80A | 95A | 115A | 150A |
Ie AC-1 |
80A | - | 125A | - | 200A | - | |
Rated operational voltage |
1000V on ~supply, 690V on supply | ||||||
Pole No. |
3P | 3P | 3P,4P | 3P | 3P,4P | 3P | |
Rated operational power in AC-3 |
220/240V |
15KW | 18.5KW | 22KW | 25KW | 30KW | 40KW |
380/400V |
22KW | 30KW | 37KW | 45KW | 55KW | 75KW | |
415/440V |
25/30KW | 37KW | 45KW | 45KW | 59KW | 80KW | |
500V |
30KW | 37KW | 55KW | 55KW | 75KW | 90KW | |
660/690V |
33KW | 37KW | 45KW | 45KW | 80KW | 100KW | |
1000V |
30KW | 37KW | 45KW | 45KW | 75KW | 90KW | |
Thermal overload relays |
class 10A |
17...50A | 17...70A | 17...80A | 17...104A | 60...150A | 60...150A |
class 20 |
17...40A | 17...65A | 17...70A | - | 60...150A | 60...150A | |
Auxiliary contacts for 9-32A,1NC and 1NO instantaneous incorporated in the contactors, with add-on blocks common to the whole;
Auxiliary contacts for 40-150A, range comprising up to 4N/C or N/O instantaneous, up to 1N/O+1N/C time delay and up to 2N/O or N/C protected contacts and 2 screen continuity terminals.
LC1-F Contactor |
Application
LC1-F series AC contactor is applicable in the circuits up to the rated voltage 1000V AC 50Hz or 60Hz,rated curent 780A, for long distance breaking circuit and frequently starting or control the motor. It also can be used for the control of distribution circuits of rated current from 200A TO 1600A.
![]() |
![]() |
![]() |
3P |
4P |
LC1-F780 |
Specification
Standard power ratings of 3-phase motors 50/60Hz in category AC-3 |
Rated operational current in AC-3 |
||||||||
220V |
380V |
660V |
up to440V |
Model |
Weight |
||||
230V |
400V |
415V |
440V |
500V |
690V |
1000V |
|||
KW |
KW |
KW |
KW |
KW |
KW |
KW |
A |
kg |
|
30 |
55 |
59 |
59 |
75 |
80 |
65 |
115 |
LC1-F115 |
3.43 |
40 |
75 |
80 |
80 |
90 |
100 |
65 |
150 |
LC1-F150 |
3.43 |
55 |
90 |
100 |
100 |
110 |
110 |
100 |
185 |
LC1-F185 |
4.65 |
63 |
110 |
110 |
110 |
129 |
129 |
100 |
225 |
LC1-F225 |
4.75 |
75 |
132 |
140 |
140 |
160 |
160 |
147 |
265 |
LC1-F265 |
7.44 |
100 |
160 |
180 |
200 |
200 |
220 |
160 |
330 |
LC1-F330 |
8.6 |
110 |
200 |
220 |
250 |
257 |
280 |
185 |
400 |
LC1-F400 |
9.1 |
147 |
250 |
280 |
295 |
355 |
335 |
335 |
500 |
LC1-F500 |
11.35 |
200 |
335 |
375 |
400 |
400 |
450 |
450 |
630 |
LC1-F630 |
18.6 |
220 |
400 |
425 |
425 |
450 |
450 |
450 |
780 |
LC1-F780 |
39.5 |
LP1-D DC Contactor |
Application
CJX2-Z(LP1-D) series DC operated AC contactor is suitable for use in the circuits up to rated voltage 660V AC 50Hz or 60Hz, and in rated current 9-95A in AC-3/380V load circuits. For remote controlling circuit making, breaking and frequent starting AC motors. It can be also combined with the auxiliary contact group, air delayer, thermal relay device etc.
![]() |
![]() |
![]() |
LP1-D09,12 |
LP1-D18,25 |
LP1-D32,40 |
![]() |
![]() |
![]() |
LP1-D50,65 |
LP1-D80 |
LP1-D95 |
Specification
Model |
Rated working current A (AC-3, 380V) |
Controlled power |
No. of the contacts |
||||
220V |
380V |
415V |
440V |
660V |
|||
CJX2-09Z(LP1-D09) |
9 |
2.2 |
4 |
4 |
4 |
5.5 |
3P+NO or 3P+NC |
CJX2-12Z(LP1-D12) |
12 |
3 |
5.5 |
5.5 |
5.5 |
7.5 |
|
CJX2-18Z(LP1-D18) |
18 |
4 |
7.5 |
9 |
9 |
9 |
|
CJX2-25Z(LP1-D25) |
25 |
5.5 |
11 |
11 |
11 |
15 |
|
CJX2-32Z(LP1-D32) |
32 |
7.5 |
15 |
15 |
15 |
18.5 |
|
CJX2-40Z(LP1-D40) |
40 |
11 |
18.5 |
22 |
22 |
30 |
3P+NO+NC |
CJX2-50Z(LP1-D50) |
50 |
15 |
22 |
25 |
30 |
33 |
|
CJX2-65Z(LP1-D65) |
65 |
18.5 |
30 |
37 |
37 |
37 |
|
CJX2-80Z(LP1-D80) |
80 |
22 |
37 |
45 |
45 |
45 |
|
CJX2-95Z(LP1-D95) |
95 |
25 |
45 |
45 |
45 |
45 |
|
CJX8(3RT) Contactor |
Application
The Series AC contactors are suitable for frequency of 50/50Hz,rated insulation voltage up to 690-1000V,rated operational current up to 7A-95A at rated operational voltage up to 380V under the utilization category AC-3, They are mainly used for making breaking electric circuits at a ling distance and for frequent staring stopping and reversing control of AC motos,They comply witch IEC947,VDE0660, GB14048.
Specification
Model |
Rated current |
Type |
Voltage |
|
![]() |
CJX8-1016 |
S00 9A |
CJX81016-1AB01 CJX81016-1AK61 CJX81016-1AR11 con(INA+ONC) |
24V 120V 220V 440V |
![]() |
CJX8-1026 |
S0 9A |
CJX81016-1AB60 CJX81016-1AN20 CJX81016-1AR10 |
120V 220V 440V |
![]() |
CJX8-1034 |
S2 32A |
CJX81034-1AJ16 CJX81034-1AN16 CJX81034-1AR16 |
115V 220V 440V |
![]() |
CJX8-1036 |
S2 50A |
CJX81036-1AJ16 CJX81036-1AN16 CJX81036-1AR16 |
115V 220V 440V |
![]() |
CJX8-1045 |
S3 80A |
CJX81045-1AJ16 CJX81045-1AN16 CJX81045-1AR16 |
115V 220V 440V |
Contactor Auxiliary |
Rated current |
Type |
Number of contacts |
![]() |
- |
H1911-1FA22 H1921-1FA22 H1911-1EA11 |
2NA+2NC |
B Series Contactor |
B series AC Contactors are mainly used in 50/60Hz electrical lines of the rated voltageup to 660V AC and rated current up to 370A, are applicable for remote making and breaking ofelectrical lines or frequent control of AC motors, having no-voltage protection. Usually, it can becombined with JR29 series thermal relay to form electromagnetic starters which have overloadand open-phase protection. It complies with IEC947-4-1.
![]() ![]() |
Specification
| Type | B9 | B12 | B16 | B25 | B30 | B37 | B45 | B65 | B85 | B105 | B170 | B250 | B370 | |
| The highest controlpower (kw) | 220V | 2.2 | 3 | 4 | 6.5 | 9 | 10 | 13 | 16 | 20 | 28 | 46 | 60 | 32 |
| 380V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 33 | 45 | 55 | 90 | 132 | 200 | |
| 500V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 40 | 50 | 7 | 110 | 160 | 250 | |
| 660V | 4 | 5.5 | 5.5 | 11 | 15 | 18.5 | 22 | 40 | 50 | 75 | 110 | 160 | 250 | |
| Rated heating current Ith (A) | 16 | 20 | 25 | 40 | 45 | 45 | 60 | 80 | 100 | 140 | 230 | 300 | 400 | |
| Rated working currentAC2/AC3/AC4 | 380V | 8.5 | 11.5 | 15.5 | 22 | 30 | 37 | 44 | 45 | 85 | 105 | 170 | 245 | 370 |
| 660V | 3.5 | 4.9 | 6.7 | 13 | 17.5 | 21 | 25 | 3.5 | 55 | 82 | 118 | 170 | 268 | |
| Rated holding power of aholding coil/pull-in (VA/W) | 9/2.2 60/50 |
9/2.2 60/50 |
9/2.2 60/50 |
10/3 85/65 |
10/3 85/65 |
22/5 175/25 |
22/5 125 |
30/8 270/130 |
30/8 270/130 |
32/9 510/280 |
60/15 790/460 |
66/16 1100/600 |
100/27 900/350 |
|
| CA7 | CA9-11 CA9-20 | CA11-11 CA-20 |
![]() |
![]() |
![]() |
| B9,B12,B16,B25,B30,37 | B45,B65,B85,B105 | B170,B250,B370 |
| TP Type pneumatic timer delaying the operation of next stage of a control loop | |||
| Start delay | TPD40 0.3~40s | Relief delay | TP140 0.3~40s |
| TPD180 10~180s | TP1180 10~180s | ||
Outline and Installation Dimension
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Type | A max | B max | C max | D max | E | F | G | H |
| B105 | 118 | 154 | 137 | 140±0.35 | 35±0.15 | Φ6.5 | Φ6.5 | ≥15 |
| B170 | 134 | 165 | 152 | 150±0.35 | 40±0.15 | 7.5 | 7.5 | ≤15 |
| B250 | 167 | 207 | 193 | 190±0.45 | 50±0.17 | 5.5 | 8.5 | ≥15 |
| B370 | 202 | 252 | 221 | 220±0.52 | 60±0.20 | 6.5 | 8.5 | ≤15 |
LC4 4POLE Contactor |
![]() |
![]() |
LC4-09004 |
LC4-50004 |
Specifications
AC-3 AC-1 440V 0 ≤40°C(A) |
Rated noncon- ductive voltage |
Power poles |
Reference |
|
Control |
Circuit: A. C. |
|||
9 |
25 |
690 |
4 - |
LC4-09004 |
2 2 |
LC4-09008 |
|||
12 |
25 |
690 |
4 - |
LC4-12004 |
2 2 |
LC4-12008 |
|||
25 |
40 |
690 |
4 - |
LC4-25004 |
2 2 |
LC4-25008 |
|||
40 |
60 |
690 |
4 - |
LC4-40004 |
2 2 |
LC4-40008 |
|||
50 |
80 |
690 |
4 - |
LC4-50004 |
2 2 |
LC4-50008 |
|||
65 |
80 |
690 |
4 - |
LC4-65004 |
2 2 |
LC4-65008 |
|||
80 |
125 |
690 |
4 - |
LC4-80004 |
2 2 |
LC4-80008 |
|||
95 |
125 |
690 |
4 - |
LC4-95004 |
2 2 |
LC4-95008 |
|||
S-P Magnetic Contactor |
Type |
|
|
|
|
||||||||||
Rated capacitance of motor |
KW |
HP |
A |
KW |
HP |
A |
KW |
HP |
A |
KW |
HP |
A |
||
CNS C4084 JIS C8325 JEM 1038 AC3 Rated capacity |
Single phase |
100~110V |
0.55 |
0.75 |
12 |
0.55 |
0.75 |
12 |
0.75 |
1 |
16 |
1.1 |
1.5 |
24 |
200~220V |
1.1 |
1.5 |
12 |
1.1 |
1.5 |
12 |
1.5 |
2 |
16 |
2.2 |
3 |
24 |
||
three phase |
200~220V |
3 |
4 |
12 |
3 |
4 |
12 |
3.7 |
5 |
16 |
5.5 |
7.5 |
24 |
|
380~440V |
4 |
5.5 |
9 |
4 |
5.5 |
9 |
5.5 |
7.5 |
12 |
11 |
15 |
21 |
||
500~550V |
4 |
5.5 |
7 |
4 |
5.5 |
7 |
5.5 |
7.5 |
10 |
11 |
15 |
17 |
||
Continuous power-on current(ith)(a)AC1 resistance load |
20 |
20 |
30 |
40 |
||||||||||
Rated insulation voltage |
AC600 |
AC600 |
AC600 |
AC600 |
||||||||||
AC3 Rated capacity |
three phase |
240V |
3.5 |
4.5 |
13 |
3.5 |
4.5 |
13 |
4.5 |
6 |
18 |
5.5 |
7.5 |
24 |
440V |
5.5 |
7.5 |
12 |
5.5 |
7.5 |
12 |
7.5 |
10 |
16 |
11 |
15 |
21 |
||
550V |
5.5 |
7.5 |
9 |
5.5 |
7.5 |
9 |
7.5 |
10 |
13 |
11 |
15 |
17 |
||
660V |
5.5 |
7.5 |
7 |
5.5 |
7.5 |
7 |
7.5 |
10 |
9 |
11 |
15 |
14 |
||
Continuous power-on current(ith)(a)AC1 resistance load |
20 |
20 |
30 |
32 |
||||||||||
Rated insulation voltage |
AC600 |
AC600 |
AC600 |
AC600 |
||||||||||
Rated capacity |
Single phase |
110~120V |
0.5 |
9.8 |
0.5 |
9.8 |
1 |
16 |
2 |
24 |
||||
220~240V |
2 |
12 |
2 |
12 |
3 |
17 |
3 |
17 |
||||||
three phase |
220~240V |
3 |
9.6 |
3 |
9.6 |
5 |
15.2 |
7.5 |
22 |
|||||
440~480V |
7.5 |
11 |
7.5 |
11 |
10 |
14 |
15 |
21 |
||||||
550~600V |
10 |
11 |
10 |
11 |
10 |
11 |
15 |
17 |
||||||
Continuous power-on current(A) |
24 |
24 |
30 |
35 |
||||||||||
Rated insulation voltage |
AC600 |
AC600 |
AC600 |
|||||||||||
NEMA grade |
00 |
00 |
0 |
1 |
||||||||||
Auxiliary Connector |
Connector constitution |
Standard |
1V) |
1a1b (1NO 1NC) |
1a1b (1NO 1NC) |
1a1b (1NO 1NC) |
||||||||
Special |
1b(1NC) |
2a(2NO) |
- |
- |
||||||||||
IEC 60947-5-1 EN 60947-5-1 Rated current(A) |
110v |
6 |
6 |
6 |
6 |
|||||||||
220v |
5 |
5 |
5 |
5 |
||||||||||
440v |
3 |
3 |
3 |
3 |
||||||||||
550v |
3 |
3 |
3 |
3 |
||||||||||
Continuous power-on current(A) |
16 |
16 |
16 |
16 |
||||||||||
Degree of auxiliary connector |
A600 |
A600 |
A600 |
A600 |
||||||||||
Mechanical life |
100 |
100 |
100 |
100 |
||||||||||
Electrial life |
500 |
500 |
500 |
500 |
||||||||||
Weight |
0.33 |
0.35 |
0.37 |
0.38 |
||||||||||
LA1-D Contact Blocks |
Application
LA1-D series auxiliary contact blocks are installed at the top of LA2-D control relay or LC1-D AC contactor for expanding the couples of auxiliary contacts points. Owing to adopting the contacting functions of sliding friction, the item can be self-cleaning & ensure the electric circuit to be reliable.
![]() |
![]() |
LA1-DN11 |
LA1-DN22 |
Specification
| Model | LA1-D02 | LA1-D04 | LA1-D11 | LA1-D13 | LA1-D20 | LA1-D22 | LA1-D31 | LA1-D40 |
| Contact number | 2NC | 4NC | NO+NC | 1NO+3NC | 2NO | 2NO+2NC | 3NO+1NC | 4NO |
LA2-D Contact Blocks |
Application
LA2-D timer delay auxiliary contact blocks are combined with LC-D AC contactor & LA1-D auxiliary contact block into LC3-D star delta reduced voltage starter to start motor.
![]() |
Specification
Model |
Delay range |
Numer of the delay contacts |
LA2-DT0 |
0.1~3s |
NO+NC |
LA2-DT2 |
0.1~30s |
NO+NC |
LA2-DT4 |
10~180s |
NO+NC |
LA3-DR2 |
0.1~30s |
NO+NC |
LA3-DR4 |
10~180s |
NO+NC |
LA3-DR2 |
0.1~3s |
NO+NC |
Bobbin Of AC Contactor |
![]() |
![]() |
![]() |
![]() |
LX1-D2 |
LX1-FJ |
LX1-D6 |
LX1-FF |
Specification
LX1-D2: |
Used for Contactor |
LC1-D09 to LC1-D18 |
LX1-D4: |
LC1-D25 to LC1-D32 |
|
LX1-D6: |
LC1-D40 to LC1-D95 |
|
LX1-FF: |
LC1-F115 to LC1-F150 |
|
LX1-FG: |
LC1-F185 to LC1-F225 |
|
LX1-FH: |
LC1-F265 to LC1-F330 |
|
LX1-FJ: |
LC1-F400 |
|
LX1-FK: |
LC1-F500 |
|
LX1-FL: |
LC1-F630 |
|
LX1-FK(1): |
LC1-F780 |