A large and drighr meter with a scale length of 80mm and its sensitivity of 44μA at full scale
Series capacitor terminal(OUTPUT)blocks DC to enadle measurement of only AC components.
Fuse protection
DC Voltae:0.1/0.5/2.5/10/50/250/1000V ±3%f.s
AC Voltage:10/50/250/1000V ±4%f.s
DC Current:50μ/2.5m/25m/250mA ±3%f.s
Resistance: ×1/×10/×1K/×10KΩ MAX ±3% of arc
dB:-10dB~+22dB
Ll:150μ/15m/150mA
hFE:0~1000
Dimension:150(L)×100(W)×36(H)mm
Weight:Approx.250g(including battery)
YX-360TRN
A large and drighr meter with a scale length of 80mm and its
sensitivity of at full scale
Fuse protection
DC Voltae:0.1/0.5/2.5/10/50/250/1000V ±3%f.s
AC Voltage:10/50/250/1000V ±4%f.s
DC Current:50μ/2.5m/25m/250mA ±3%f.s
Resistance: ×1/×10/×1K/×10KΩ MAX ±3%f.s
dB:-10dB-+22dB
Ll:150μ/15m/150mA
hFE:0~1000
Dimension:150(L)×100(W)×56(H)mm
Weight:Approx.280g(including barrery)
ST-370R(MF-360B)
A large and drighr meter with a scale length of 80mm and its sensitivity of 44μA at full scale.
Measures DC current 10A(MAX)
Fuse protection
DC Voltae:0.1/0.5/2.5/10/50/250/1000V ±3%f.s
AC Voltage:10/50/250/1000V ±4%f.s
DC Current:50μ/2.5m/25m/250mA/10A ±3%f.s
Resistance: ×1/×10/×1K/×10KΩ MAX ±3% of arc.
dB:-10dB~+22dB
Ll:150μ/15m/150mA
hFE:0~1000
Dimension:150(L)×100(W)×36(H)mm
Weight:Approx.250g(including battery)
YX-360TRN-A
A large and drighr meter with a scale length of 80mm and its
sensitivity of 44μA at full scale
Series capacitor terminal(OUTPUT)blocks DC to enable measurement of only AC components.
Fuse protection
DC Voltae:0.1/0.5/2.5/10/50/250/1000V ±3%f.s
AC Voltage:10/50/250/1000V ±4%f.s
DC Current:50μ/2.5m/25m/250mA ±3%f.s
Resistance: ×1/×10/×100/×1K/10KΩ ±3% of arc
dB:-10dB~+22dB
Ll:150μ/1.5m/15m/150mA
hFE:0~1000
Dimension:150(L)×100(W)×36(H)mm
Weight:Approx.250g(including battery)
YX-360TRE
A large and drighr meter with a scale length of 80mm and its sensitivity of at full scale
Series capacitor terminal(OUTPUT)blocks DC to enadle measurement of only AC components.
Fuse protection
Measures Hfe of transistor directly
DC Voltae:0.1/0.5/2.5/10/50/250/1000V ±3%f.s
AC Voltage:10/50/250/1000V ±4%f.s
DC Current:50μ/2.5m/25m/250mA ±3%f.s
Resistance: ×1/×10/×100/1K/10K MAXΩ ±3%of arc.
dB:-10dB~+22dBLl:150μ/15m/150mA
hFE:0~1000Dimension:150(L)×100(W)×56(H)mm
Weight:Approx.280g(including barrery)
YX-360TRE-P
A large and drighr meter with a scale length of 80mm and its sensitivity of 44μA at full scale.
Series capacitor terminal(OUTPUT)blocks DC to enadle measurement of only AC components.
Continuiy check with buzzer sound.
Fuse protection
DC Voltae:0.1/0.5/2.5/10/50/250/1000V ±3%f.s
AC Voltage:10/50/250/1000V ±4%f.s
DC Current:50μ/2.5m/25m/250mA ±3%f.s
Resistance: ×1/×10/×100/×1K/10KΩ MAX ±3%f.s
dB:-10dB~+22dB
Ll:150μ/1.5m/15m/150mA
hFE:0~1000
Dimension:150(L)×100(W)×36(H)mm
Weight:Approx.250g(including battery)
YX-360TRE-B
Wide measuring range with 24 ranges rotary switch and series Capacitor terminal(OUTPUT)to betect only AC signals
Zero center meter (Nul metre)function
Continuity check with LED indicator
Barrery check & Fuse protection
Logic tester (w/logic probe)and TR FET tester(w/TR FET connector)
DC Voltae:0.1/0.5/2.5/10/250/1000V ±3% f.s
DC Voltage:(Null meter): ±5/±25V±3% f.s.
AC Voltage:2.5/10/50/250/1000V ±3%f .s.
DC Current:50μ/2.5m/25m/250A ±3% f.s.
Resistance: ×1/×10/100/1K/×10KΩ±3% of arc.
dB:-10Db ~+10dB
Ll:150μ/1.5m/15m/150mA
LV:0V-3V
hFE:0~1000
Battery check:1.5V
Dimension:150(L)×100(W)×36(H)mm
Weight:Approx.240g(including battery)
YX-361TR
A taut-band type is adopted in the meter departent.The shock-proof
Designs enable instrument to withstand shock even when it is dropped on a conctere floor fron one-meter height.
This unit can determine the capacity of manganese and alkaline batteries by measurind their voltage when the load is 10Ω
Battery Check function
DC Voltage:0.25/2.5/10/50/250/500/1000V ±5%f.s.
AC Voltage:10/50/250500/1000V ±5%f.s.
DC Current:0.25m/2.5m/25m/500mA ±5%f.s.
Resistance:×1/×10/×1KΩ
Ll:150μ/15m/150mA
Dimension:160(L)×125(W)×42(H)mm
Weight:Approx.300g(including battery)
YX-360TRC
This in strument is portadle multitester designated for measrement of weak current circuits Panel face protection cover. Which serves also as a stand band meter of prop shock type with high sensitivity are emploued.Overload protecrion
Overload protection
DC Voltage:0.25/2.5/10/50/250/500/1000V ±3%f.s.
AC Voltage:10/50/250/500/1000V ±4% f.s DC Current:50μ/2.5m/25m/250mA ±3%f.s.
Resistance:×1/×10/×1K×100KΩ
Capaciance:0.01μF~10μF
DB:-10Db~+22dB
Ll:150μ/150μ/15m/150mA
Dimension:160(L)×125(W)×42(H)mm
Weight:Approx.320 g(including battery)
YX-360TRD
This in strument is portadle multitester designated for measrement of weak current circuits Panel face protection cover. Which serves also as a stand band meter of prop shock type with high sensitivity are emploued.
Overload protecrion
DC Voltage:.0.1/0.25/2.5/10/50/250/1000 ±3% f.s DC Voltage:(null): ±5/±25 ±5%f.s
AC Voltage:10/50/250/750v ±4%f.s
DC Voltage: 50μ/2.5m/25m/250mA ±3%f.s.
Resistance:×1/×10/×100/×1KΩ ±3% of arc
Capaciance:0.01μF~10μF
dB:-10Db~+22dB
Ll:150μ/150μ/15m/150mA
Dimension:160(L)×125(W)×42(H)mm
Weight:Approx.320 g(including battery)
YX-360TRF
This in strument is portadle multitester designated for measrement of weak current circuits Panel face protection cover.
Which serves also as a stand band meter of prop shock type with high sensitivity are emploued.
Overload protecrion
Measures hFE of transistor directly
DC Voltage: 0.1/0.25/2.5/10/50/250/1000 ±3%f.s
DC Voltage:10/50/250/1000V ± 4f.s DC Voltage: 50μ/2.5m/25m/250mA ±3%f.s.
Resistance:×1/×10/×100/×1KΩ ±3%of arc
Capaciance:0.01μF~10μF
DB:-10Db~+22dB
Ll:1.5μ/150μ/15m/150mA
Dimension:160(L)×125(W)×42(H)mm
Weight:Approx.320 g(including battery)
YX-360TRG
A large and drighr meter with a scale length of 80mm and its sensitivity of 44 μat full scale
Series capacitor terminal(OUTPUT)blocks DC to enable measurement of only AC components.
Fuse protection
DC Voltae:0.1/0.5/2.5/10/50/250/1000V ±3% f.s
AC Voltage:10/50/250/1000V ±4% f.s
DC Current:50μ/2.5m/25m/250mA ±3% f.s
Resistance: ×1/×10/×1K/×10KΩ ±3% of arc.
dB:-10dB-+22dB
Ll:150μ/1.5/15m/150mA
hFE:0~1000
Dimension:150(L)×100(W)×36(H)mm
Weight:Approx.280g(including battery)
YX-360N
A large and drighr meter with a scale length of 80mm and its sensitivity of 44μA at full scale
Series capacitor terminal(OUTPUT)blocks DC to enadle measurement of only AC components.
Fuse protection
DC Voltae:0.1/0.5/2.5/10/50/250/1000V ±3%f.s
AC Voltage:10/50/250/1000V ±4%f.s
DC Current:50μ/2.5m/25m/250mA ±3%f.s
Resistance: ×1/×10/×1K/10KΩ ±3% of arc.
dB:-10dB-+22dB
Ll:150μ/15m/150mA
hFE:0~1000
Dimension:150(L)×100(W)×56(H)mm
Weight:Approx.280g(including battery)
YX-360TR
Zero center meter(Null meter)function
Continuity check with buzzer sound.
Fuse & Diode protect.
DC Voltae:0.3/3/12/30/120/600V ±3% f.s
AC Voltage:(Null meter): ±6/±30V ±5% f.s.
DC Current:60μ/30m/0.3A ±3%f.s
Resistance: ×1/×10/1K/1KΩ ±3% of arc.
Battery check:1.5V
Capacitance:-1μF~500μF
Dimension:144(L)×99(W)×41(H)mm
Weight:Approx.240g(including battery)
SP-21
Wide measuring range with 21 ranges rotary switch
Automatically simultaneous TR quality & type checker.
Continuity check with LED indicator
Barrery check with buzzer sound.
DC Voltae:120m/3/12/30/120/300/1200V ±4%f.s
AC Voltage:6/30/120/300/1200V ±5%f.s.
DC Voltage:50μ/3m/30m/300m/12A ±4%f.s.
Resistance: ×1/×10/×100/×1K/×10KΩ ±4% of arc.
dB:-10Db ~+17dB
Ll:150μ/1.5m/15m/150mA
Dimension:165(L)×105(W)×40(H)mm
Weight:Approx.340g(including battery)
KS-560TRE
A large and drighr meter with a scale length of 80mm and its
sensitivity of at full scale
Series capacitor terminal(OUTPUT)blocks DC to enadle measurement of only AC components.A
24 hours
By fax & e-mail as below
Tel:0086-577-62737672
Fax:0086-577-62737671 sunshine@sunshinele.com
24 hours response guaranteed!