| AC. DC Ammeter |
 |
Model:
90° SF-96-3 SF-72-3 SF-48-3 SF-144-3
240° SF-96-3 SF-72-3
Product description and technical parameters:
Accuracy: class 1.5
Specification: 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A
There're two standard methods for 10A-10KA use external current transformer with secondary current 1A and 5A.
Notes: For 60A 75A 100A meters,when these meters directly connected to circuit,their accuracy is class 2.5.
SF-48 is class 2.5 for 20-60A
Changeable scale:All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case
Mounting: flush mounting with bracket, the maximum mounting depth is 43 mm. |
 |
Model:
90° RC-96-8 RC-72-8
Product description and technical parameters:
Accuracy: class 1.5
Specification: 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A
There’re two standard methods for 10A-10KA use external current transformer with secondary current 1A and 5A.
Notes: For 60A 75A 100A meters,when these meters directly connected to circuit,their accuracy is class 2.5.
Changeable scale:All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case
Mounting: flush mounting with bracket, the maximum mounting depth is 43 mm. |
 |
Model:
90° SF-96-6 SF-72-6
Product description and technical parameters:
Accuracy: class 1.5
Specification: 0.1A 0.5A 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A
There’re two standard methods for 10A-10KA use external current transformer with secondary current 1A and 5A.
Notes: For 60A 75A 100A meters,when these meters directly connected to circuit,their accuracy is class 2.5.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case
Mounting: flush mounting with bracket, the maximum mounting depth is 43 mm. |
 |
Model:
90° SFC-45 SFC-10
Product description and technical parameters:
Accuracy: class 1.5
Specification: 0.1A 0.5A 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A There’re two standard methods for 10A-10KA use external current transformer with secondary current 1A and 5A.
Notes: For 60A 75A 100A meters,when these meters directly connected to circuit,their accuracy is class 2.5.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case
Mounting: flush mounting with bracket, the maximum mounting depth is 43 mm. |
 |
Model:
90° SF-80A SF-670A SF-60A SF-50A
Product description and technical parameters:
Accuracy: class 1.5
Specification: 0.1A 0.5A 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A
There’re two standard methods for 10A-10KA use external current transformer with secondary current 1A and 5A.
Notes: For 60A 75A 100A meters,when these meters directly connected to circuit,their accuracy is class 2.5.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case
Mounting: the maximum mounting depth is 43 mm. |
 |
Model:
90° SF-65A SF-52A SF-45A SF-62T2A SF-100YA
Product description and technical parameters:
Accuracy: class 1.5
Specification: 0.1A 0.5A 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A
There’re two standard methods for 10A-10KA use external current transformer with secondary current 1A and 5A.
Notes: For 60A 75A 100A meters,when these meters directly connected to circuit,their accuracy is class 2.5.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: the maximum mounting depth is 43 mm. |
 |
Model:
SFS-96 SFS-72
Product description and technical parameters:
A selector switch is built into the instrument for measurement of AC Ammeter in a three phase network.
Accuracy: class 1.5
Frequency: 50Hz
Measuring range: 0.1A/1A, 0.2A/2A, 0.3A/3A, 0.4A/4A, 0.5A/5A, 1A/15A , 5A/5A
3-Position: L1-L2,L1-L3,L2-L3(OFF-Position is available on request).
AC ammeters with 3-Position selector switch can be used for the measurement of AC current in three phase three wire system and three phase four wire system.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket, the maximum mounting depth is 43 mm. |
 |
Name:
Double Ammeter
Model:
SF-96A SF-72A
Accuracy: class 1.5
Specification: 0-100V 0-300V 0-500V
Heat resistance: Case of non-combustible plastic material.
Fatening: By means of nuts, absolutely safe, fast, robust, side-by-side.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
Model:KLY-D36A DC/AC
Display:3 1/2digital.LED display (red or green)
Accuracy:0.5%±1 digit
Stardand:IEC51-1
Auxiliary power:AC 110V±10%50/60 Hz AC 220V±10% 50/60Hz
Input signa: I DC current
Measuring range:0-20ADC,For the current over 20A can use external shunt
Consumption:<1.8VA
Max Signal Consumption:< 0.3VA
Operating environment:temperature-10℃ ~+50℃ humidity:≤85%
Storage environment:temperature-30℃~+60℃ humidity:≤70%
Heat resistance:case of non-combustible plastic material according to UL94-V0
Voltage testing:over 2000V |
| AC.DC Voltmeter |
|
 |
Model:KLY-D36V AC/DC
Display:3 1/2digital.LED display (red or green)
Accuracy:0.5%±1 digit
Stardand:IEC51-1
Auxiliary power:AC 110V±10% 50/60 Hz AC 220V±10% 50/60Hz
Input signa:I DC voltage
Measuring range:0-600V AC,For the voltage over 600v can use the potential transformer
Consumption:<1.8VA
Max Signal Consumption:< 0.3VA
Operating environment:temperature-10℃ ~+50℃ humidity:≤85%
Storage environment:temperature-30℃~+60℃ humidity:≤70%
Heat resistance:case of non-combustible plastic material according to UL94-V0
Voltage testing:over 2000V |
 |
Model:
90°SF-96 SF-72 SF-48 SF-144
240°SF-96 SF-72
Specification: 100V 300V 500V 600V
For over 450V use external voltage transformer.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
Model:
RC-96-8 RC-72-8
Specification: 30V 50V 100V 120V 150V 200V 250V 450V 500V 600V
For over 450V use external voltage transformer.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
Model:
SF-96-6 SF-72-6
Specification: 30V 50V 100V 120V 150V 200V 250V 450V 500V 600V
For over 450V use external voltage transformer.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
Model:
SFC-45 SFC-100
Specification: 30V 50V 100V 120V 150V 200V 250V 450V 500V 600V
For over 450V use external voltage transformer.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
Model:
SF-80V SF-670V SF-60V SF-50V
Specification: 30V 50V 100V 120V 150V 200V 250V 450V 500V 600V
For over 450V use external voltage transformer.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: the maximum mounting depth is 43 mm. |
 |
Model:
SF-65V SF-52V SF-45V SF-62T2V SF-100YV
Specification: 30V 50V 100V 120V 150V 200V 250V 450V 500V 600V
For over 450V use external voltage transformer.
Changeable scale: All scales with printing technique.
The dial plate with different scale, which is at the same internal value,can be changeable.But the accuracy is unchangeable.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: the maximum mounting depth is 43 mm. |
 |
Name:
Double Voltmeters
Model:
SF-96V SF-72V
Accuracy: class 1.5
Specification: 0-100V 0-300V 0-500V
Heat resistance: Case of non-combustible plastic material.
Fatening: By means of nuts, absolutely safe, fast, robust, side-by-side.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
A selector switch is built into the instrument for measurement of AC Voltmeter in a three phase network.
Model:
SF-96V SF-72V
Accuracy: class 1.5
Frequency: 50Hz
3 phase 4 wire Measuring range: 60/100V 80/150V 100/200V 150/250V 250/400V 300/500V 350V/600V
6-Position: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N(OFF Position is available on request)
3 phase 3 wire Measuring range: 100V, 150V 200V 250V 400V 500V 600V
3-Position: L1-L2,L1-L3,L2-L3(OFF-Position is available on request).
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket, the maximum mounting depth is 43 mm. |
 |
Name:
Rated Value Voltmeter
Model:
SF-96 SF-72 SF-48
Specification: 0/90-110V, 0/100-120V,0/180-240V, 0/200-240V, 0/340-420V
Heat resistance: Case of non-combustible plastic material. (comply with UL-94 V0 standard)
Fatening: By means of nuts, absolutely safe, fast, robust, side-by-side.
Mounting Depth: Max 43mm. |
| Frequency Meter |
|
 |
Mode:KLY-45
Indent:KLY-F45
Accuracy:1.0
Voltage:45-55Hz 45-65Hz 47-63Hz 57-63Hz 44-56Hz 54-66Hz 350-450Hz 450-550Hz
Voltage:100V 220V 380V 440V
build in wise:plastic drive shim
Mounting way:Modular type, external size and Scale range table see Installing Construction Drawing |
 |
Model:
90° SF-144-3 SF-96-3 SF-72-3 SF-48-3 SF-144-3
240° SF-96-3 SF-72-3
Accuracy: class 1.0
Specification:
Voltage: 50V 100V 220V 380V 440V
Frequency: 45~55Hz, 45~65Hz, 55~65Hz, 47~53Hz
Case: Non-combustile ABS plastic material is used for making external case. (comply with UL-94 V0 standard)
Fatening: By means of nuts,absolutely safe,fast,robust,side-by-side.
Mounting Depth: Max 43mm. |
 |
Model:
90°RC-96-8 RC-72-8
Accuracy: class 1.0
Specification:
Voltage: 100V 220V 380V 440V
Frequency: 45~55Hz, 45~65Hz, 55~65Hz, 47~53Hz
Case: Non-combustile ABS plastic material is used for making external case. (comply with UL-94 V0 standard)
Fatening: By means of nuts, absolutely safe, fast, robust, side-by-side.
Mounting Depth: Max 43mm. |
 |
Model:
90°SF-96-6 SF-72-6
Accuracy: class 1.0
Specification:
Voltage: 100V 220V 380V 440V
Frequency: 45~55Hz, 45~65Hz, 55~65Hz, 47~53Hz
Case: Non-combustile ABS plastic material is used for making external case. (comply with UL-94 V0 standard)
Fatening: By means of nuts, absolutely safe, fast, robust, side-by-side.
Mounting Depth: Max 43mm. |
 |
Model:
90° SFC-45 SFC-100
Accuracy: class 1.0
Specification:
Voltage: 100V 220V 380V 440V
Frequency: 45~55Hz, 45~65Hz, 55~65Hz, 47~53Hz
Case: Non-combustile ABS plastic material is used for making external case. (comply with UL-94 V0 standard)
Mounting: DIN rail, with Max 43mm. |
 |
Model:
SF-100Y
Accuracy: class 1.0
Specification:
Voltage: 50V 100V 220V 380V 440V
Frequency: 45~55Hz, 45~65Hz, 55~65Hz, 47~53Hz
Case: Non-combustile ABS plastic material is used for making external case. (comply with UL-94 V0 standard)
Fatening: By means of nuts,absolutely safe,fast,robust,side-by-side.
Mounting Depth: Max 43mm. |
 |
Name:
LED Frequency Meter
Model:
SF-96 SF-72
Accuracy: class 1.5
Voltage: 100V 220V 380V
Frequency: 45~55Hz, 45~65Hz, 55~65Hz, 47~53Hz |
 |
Name:
Reed Frequency Meter (One Row and Double Row)
Model:
SF-96 SF-72(one row)
SF-96(Double row)
Accuracy: class 1.5
Voltage: 100V 220V 380V 440V
Specification: 45~55Hz, 45~65Hz, 55~65Hz, 47~53Hz, 57~63Hz,44~56Hz,54~66Hz,450~550Hz, 450~650Hz, 550~650Hz
Frequency meters with one or two rows of horizontal reeds are used to measure frequencies of network, Vertical arrangement is available on request.
Case: Non-combustile ABS plastic material is used for making external case.
Fatening: By means of nuts, absolutely safe, fast, robust, side-by-side.
Mounting Depth: Max 43mm. |
| Power Meters |
|
 |
Model:
90°:SF-96-3 SF-72-3 SF-48-3 SF-144-3
240°:SF-96-3 SF-72-3
Accuracy: class 1.5
Specification:
Direct Voltage: Single Phase: 100V 220V 380V
3 Phase 3 Wires: 100V 220V 380V 415V
3 Phase 4 Wires: 100V 220(380)V 240(415)V
For 380/100V 500/100V 3K/100V 6K/100V10K/100V 15K/100V 15K/100V 35K/100V use external voltage transformers.
Current: 1A or 5A
The voltage circuits of the meter is connected with voltage transformers. Which secondary voltage is 100V and the current circuits connected with current transformers, which secondary current is 5A.
Wattmeters and Varmeters with converter for three-phase three wires or four wire.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
Model:
90°:RC-96-8 RC-72-8
Accuracy: class 1.5
Specification:
Direct Voltage: Single Phase: 100V 220V 380V
3 Phase 3 Wires: 100V 220V 380V 415V
3 Phase 4 Wires: 100V 220(380)V 240(415)V
For 380/100V 500/100V 3K/100V 6K/100V10K/100V 15K/100V 15K/100V 35K/100V using external voltage transformers.
Current: 1A or 5A
The voltage circuits of the meter is connected with voltage transformers. Which secondary voltage is 100V and the current circuits connected with current transformers, which secondary current is 5A.
Wattmeters and Varmeters with converter for three-phase three wires or four wire.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
Model:
90°: SF-96-6 SF-72-6
Accuracy: class 1.5
Specification:
Direct Voltage: Single Phase: 100V 220V 380V
3 Phase 3 Wires: 100V 220V 380V 415V
3 Phase 4 Wires: 100V 220(380)V 240(415)V
For 380/100V 500/100V 3K/100V 6K/100V10K/100V 15K/100V 15K/100V 35K/100V using external voltage transformers.
Current: 1A or 5A
The voltage circuits of the meter is connected with voltage transformers. Which secondary voltage is 100V and the current circuits connected with current transformers, which secondary current is 5A.
Wattmeters and Varmeters with converter for three-phase three wires or four wire.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
 |
DIN rail Power Meter
Wattmeter Model: SF-W45
Accuracy: class 1.5
Specification:
Direct Voltage: Single Phase: 100V 220V 380V
3 Phase 3 Wires: 100V 220V 380V 415V
3 Phase 4 Wires: 57.7(100)V,220(380)V
For 380/100V 500/100V 3K/100V 6K/100V10K/100V 15K/100V 15K/100V 35K/100V using external voltage transformers.
Current: 1A or 5A
The voltage circuits of the meter is connected with voltage transformers. Which secondary voltage is 100V, directly when less than 450V and the current circuits connected with current transformers, which secondary current is 5A or 1A.
Wattmeters and Varmeters with converter for three-phase three wires or four wire and single phase with balanced or unbalanced load.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: DIN rail. |
 |
Model:
90°: SF-80 SF-670 SF-60 SF-50
Accuracy: class 1.5
Specification:
Direct Voltage: Single Phase: 100V 220V 380V
3 Phase 3 Wires: 100V 220V 380V 415V
3 Phase 4 Wires: 100V 220(380)V 240(415)V
For 380/100V 500/100V 3K/100V 6K/100V10K/100V 15K/100V 15K/100V 35K/100V using external voltage transformers.
Current: 1A or 5A
The voltage circuits of the meter is connected with voltage transformers. Which secondary voltage is 100V and the current circuits connected with current transformers, which secondary current is 5A.
Wattmeters and Varmeters with converter for three-phase three wires or four wire.
Case: Non-combustile ABS plastic material is used for making external case.
Mounting: flush mounting with bracket & slippage type, the maximum mounting depth is 43 mm. |
| Synchronoscope meters |
|
 |
Phase synchronization measures the frequency of 50Hz or 60Hz between two single phase or three-phase alternating current systems, or between system and generator.
Model: SF-96 SF-72
Specification: 100V 220V 380V 440V
Working time: Max 15min |
 |
Model: SF-96
Electronic Synchronoscope meters |
| Elapsed Time Meter |
|
 |
Specifications & Feature
Elapsed Time Meter or Hours Run Meters
Model: CP-H96 CP-H72 CP-H48
> Elapsed time meters features a seven-digit readout with no reset function, making them virtually tamper proof. All hour meters are connected in parallel with the equipment being monitored. The synchronous motor provides accurate hour indication. The nominal mark is H.
Display: 99999.99
Voltage: AC/DC 12V 24V 60V 100V 200V 380V
Burden: 2.5VA
Mounting: flush mounting with bracket
Note: CP-H48 is joint installation with pack, the mounting depth is 65mm |
| Phase sequence indicators |
 |
Specifications & Feature
Phase Sequence Indicator
Model: CP-SI 96, CP-SI 72
> This indicator is designed for easy testing of phase sequence In three-phase systems with a permissible operating voltage up to 500V.For short connections, not longer than 5 minutes for one test, a push-button switch is placed on the front plate. A disc with an indicating arrow rotates in the direction of the arrow, if the three phases are properly connected, otherwise the disc rotates in the other direction .By changing of two wires, the phase sequence will be corrected to corresponding designation of the terminals.The norminal Mark is SI.
Specification:
Voltage: 100-380V 150-500V
Working time: not longer than 5 minutes.
Mounting: flush mounting with bracket |
|