Current Transformer
![]() DM |
MSQ |
![]() DP |
![]() MES |
![]() DS |
NSQ |
DX |
CDS |
RED & EMC |
![]() MR |
![]() PR |
![]() RCT |
![]() D363 & D364 |
SFT |
DM Current Transformers |
![]() |
![]() |
![]() |
Specification:
Type |
Rated current (A) |
Rated Burdem (VA) |
Accuracy class |
Weight (kg) |
DM-20 |
15/5 |
- |
1.0 |
|
20/5 |
- |
1.0 |
||
25/5 |
- |
1.0 |
||
30/5 |
- |
1.0 |
||
40/5 |
- |
1.0 |
||
50/5 |
1 |
1.0 |
||
60/5 |
1 |
1.0 |
||
75/5 |
1.5 |
1.0 |
||
80/5 |
1.5 |
1.0 |
||
100/5 |
2.5 |
1.0 |
||
125/5 |
2.5 |
0.5 |
||
150/5 |
3 |
0.5 |
||
200/5 |
5 |
0.5 |
||
250/5 |
5 |
0.5 |
||
300/5 |
5 |
0.5 |
Outline Drawing:

MSQ Current Transformers |
General
Electric Ratings: AC50-60Hz, ≤0.72KV
Application: Measurement of energy, current and relaying protection; for indoor application;
Mounting modes: Busbar of bottom plate fixing to any diretion;
Technical characteristics of current transformers:
With BusBar
Type |
Rated current(A) |
Rated power(VA) |
Overall and mounting dimension |
|
Class:0.5 |
Class:1 |
|||
![]() |
30/5 |
5-10 |
5-10 |
With Bar: Installation screw(M8X20) which are used on the |
40/5 |
5-10 |
5-10 |
||
20/5 |
5-10 |
5-10 |
||
60/5 |
5-10 |
5-10 |
||
75/5 |
5-10 |
5-10 |
||
80/5 |
5-10 |
5-10 |
||
100/5 |
5-10 |
5-10 |
||
120/5 |
5-10 |
5-10 |
||
125/5 |
5-10 |
5-10 |
||
200/5 |
5-10 |
5-10 |
||
250/5 |
5-10 |
5-10 |
||
WINDOWS TYPE
Bar: 30x10mm conductor: Ø20mm
Type |
Rated current(A) |
Rated power(VA) |
Overall and mounting dimension |
|
Class:0.5 |
Class:1 |
|||
![]() |
30/5 |
1 |
![]() |
|
40/5 |
1 |
|||
50/5 |
1 |
|||
60/5 |
1 |
|||
75/5 |
1 |
1.5 |
||
80/5 |
1.5 |
2.5 |
||
100/5 |
2.5 |
5-10 |
||
150/5 |
5-10 |
5-10 |
||
200/5 |
5-10 |
5-10 |
||
250/5 |
5-10 |
5-10 |
||
WINDOWS TYPE
Bar: 40x10mm conductor: Ø30mm
Type |
Rated current(A) |
Rated power(VA) |
Overall and mounting dimension |
|
Class:0.5 |
Class:1 |
|||
![]() |
100/5 |
2.5 |
2.5 |
![]() |
150/5 |
3 |
5 |
||
200/5 |
5 |
5-10 |
||
250/5 |
5-10 |
5-10 |
||
300/5 |
5-10 |
5-10 |
||
400/5 |
5-10 |
5-10 |
||
500/5 |
5-10 |
5-10 |
||
WINDOWS TYPE
Bar: 60x20mm conductor: Ø40mm
Type |
Rated current(A) |
Rated power(VA) |
Overall and mounting dimension |
|
Class:0.5 |
Class:1 |
|||
![]() |
250/5 |
5 |
5 |
![]() |
300/5 |
5 |
5 |
||
400/5 |
5-10 |
5-10 |
||
500/5 |
5-10 |
5-15 |
||
600/5 |
5-10 |
10-15 |
||
750/5 |
10-15 |
10-15 |
||
800/5 |
10-15 |
10-15 |
||
1000/5 |
15 |
15 |
||
WINDOWS TYPE
Bar: 80x30mm or 80x10mm conductor: Ø85mm
Type |
Rated current(A) |
Rated power(VA) |
Overall and mounting dimension |
|
Class:0.5 |
Class:1 |
|||
![]() |
750/5 |
15 |
15 |
![]() |
800/5 |
15 |
15 |
||
1000/5 |
15 |
15 |
||
1200/5 |
15 |
15 |
||
1500/5 |
15 |
15 |
||
WINDOWS TYPE
Bar: 80x30mm or 100x10mm conductor: Ø60mm
Type |
Rated current(A) |
Rated power(VA) |
Overall and mounting dimension |
|
Class:0.5 |
Class:1 |
|||
![]() |
1500/5 |
15 |
15 |
![]() |
1600/5 |
15 |
15 |
||
2000/5 |
15 |
15 |
||
2250/5 |
15 |
15 |
||
2500/5 |
15 |
15 |
||
3000/5 |
15 |
15 |
||
WINDOWS TYPE
Bar:126x58mm or 126x10mm conductor: Ø125mm
Type |
Rated current(A) |
Rated power(VA) |
Overall and mounting dimension |
|
Class:0.5 |
Class:1 |
|||
![]() |
1500/5 |
15 |
30 |
![]() |
2000/5 |
15 |
30 |
||
3000/5 |
15 |
30 |
||
4000/5 |
15 |
30 |
||
5000/5 |
15 |
30 |
||
DP Current Transformers |
![]() |
Split core current transformers DP series:
The DP series of current transformers have been especially designed to facilitate their installation in new or already existing networks. Thanks to its split core they may be installed without opening any cable or bus bar circuit.
The connection of conventional CTs usually requires the interruption of the primary side circuit to pass cables or bus bars through the transformer core or to connect such cables to the primary terminals. The DP series transformers core may be easily opened and they may be installed and connected without any supply interruption, thus saving time and installation costs.
The main features of DP transformers are:
-Small size and easy mounting
-Wide inner window, allowing clamping of big cables or bus bars
-Wide range of sizes to accomodate all the existing installations
-High accuracy and reliability
Split core current transformers DP series:
| Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: |
100A-5000A 5A, 1A IEC44-1, BS7626 0.72/3kV 50/60Hz 1VA-30VA 0.5, 1.0, 3.0 Ith=100xIn FS<5 |
Specification:
Model |
Nominal current ratio |
|
Class:0.5 |
||
VA |
||
DP-23 |
100 |
- |
150 |
- |
|
200 |
- |
|
250 |
- |
|
300 |
1.5 |
|
400 |
2.5 |
|
DP-58 |
250 |
1.5 |
300 |
1.5 |
|
400 |
1.5 |
|
500 |
2.5 |
|
600 |
2.5 |
|
750 |
2.5 |
|
800 |
2.5 |
|
1000 |
5 |
|
DP-88 |
250 |
1.5 |
300 |
1.5 |
|
400 |
1.5 |
|
500 |
2.5 |
|
600 |
2.5 |
|
750 |
2.5 |
|
800 |
2.5 |
|
1000 |
5 |
|
DP-812 |
500 |
2.5 |
600 |
2.5 |
|
750 |
2.5 |
|
800 |
2.5 |
|
1000 |
6 |
|
1200 |
6 |
|
1250 |
7.5 |
|
1500 |
7.5 |
|
DP-816 |
1000 |
1. |
1500 |
15 |
|
2000 |
15 |
|
2500 |
15 |
|
3000 |
20 |
|
4000 |
20 |
|
5000 |
20 |
Dimension of case (mm):
Model |
A |
B |
C |
D |
E |
F |
G |
H |
I |
Weight(kg) |
|
DP-23 |
20 |
30 |
51 |
89 |
111 |
34 |
47 |
40 |
32 |
0.75 |
|
DP-58 |
50 |
80 |
78 |
114 |
145 |
32 |
32 |
32 |
33 |
0.90 |
|
DP-88 |
80 |
80 |
108 |
144 |
145 |
32 |
32 |
32 |
33 |
1.05 |
|
DP-812 |
80 |
120 |
108 |
144 |
185 |
32 |
32 |
32 |
33 |
1.25 |
|
DP-816 |
80 |
160 |
120 |
184 |
245 |
52 |
52 |
52 |
38 |
4.3 |
|
Outline Drawing:


MES Current Transformers |
![]() |
Split core current transformers MES series:
The MES series of current transformer have beautiful outline and Convenient for mounting in many ways. The most current transform need the special mounting and the MES series used the mounting of DIN typing With a lot of times. The protective cover for the terminal block used the switching device with Safety and quick.
MES guide rail type CT :
| Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: |
5A-3000A 5A, 1A VDE0414, BS7626, IEC44-1 0.72/3KV 50-60Hz 2.5VA, 5VA, 10VA, 15VA 0.5, 1.0 Ith=100x1h FS<5 |
Dimension of case [mm]:
Model |
A |
B |
C |
D |
E |
F |
G |
MES-62/30 |
81 |
47 |
30 |
35 |
71 |
31 |
62 |
MES-62/40 |
81 |
47 |
30 |
35 |
71 |
41 |
62 |
MES-30 |
88 |
52 |
30 |
41 |
77 |
31 |
80 |
MES-40 |
88 |
52 |
30 |
41 |
77 |
41 |
80 |
MES-60 |
117 |
57 |
50 |
184 |
77 |
61 |
101 |
MES-100 |
115 |
53 |
86 |
38 |
74 |
101 |
145 |
Technical date & Sepecification
Type |
Rated current (A) |
Rated power (VA)
|
|
Class:0.5 |
Class:1 |
||
MES-62/30 |
30/5 40/5 50/5 60/5 75/5 100/5 150/5 200/5 |
- - - - - 1.5 2 2.5 |
1 1 1 1.5 1.5 2.5 3 5 |
MES-62/40 |
60/5 75/5 100/5 150/5 200/5 250/5 300/5 |
- - 1 1.5 2.5 3 5 |
1 1 2 2.5 5 5 7.5 |
MES-30 |
30/5 50/5 60/5 75/5 100/5 150/5 200/5 |
- - - - 1.5 2.5 5 |
1 1 1.5 1.5 2.5 5 7.5 |
MES-40 |
100/5 150/5 200/5 250/5 300/5 400/5 500/5 |
1.5 2.5 5 5 10 10 10 |
2.5 5 5 5 15 15 15 |
MES-60 |
600/5 800/5 1000/5 1200/5 |
15 15 15 15 |
20 20 20 20 |
MES-100 |
1000/5 1200/5 1500/5 1600/5 2000/5 2500/5 3000/5 |
15 15 15 15 15 15 15 |
30 30 30 30 30 30 30 |
Outline Drawing:

DS Current Transformers |
![]() |
![]() |
![]() |
|
![]() |
![]() |
![]() |
![]() |
Technical data& Specification:
Model |
Ratel current(A) Primary/Secondary |
Busbar Hole Dimension |
Rated Burden(VA) |
Accuracy class |
Rated Voltage |
Rated Frequency |
DSM-20B |
50/5A-200/5A |
1.5-3 |
1.0 |
660V |
50/60Hz |
|
DSM-20 |
50/5A-200/5A |
20x10mm |
1.5-3 |
1.0 |
660V |
50/60Hz |
DSM-30 |
50/5A-200/5A |
20x10mm |
1.5-3 |
1.0 |
660V |
50/60Hz |
DSM-30 |
50/5A-300/5A |
30x10mm |
2.5-5 |
1.0 |
660V |
50/60Hz |
DS-40 |
150/5A-800/5A |
40x10mm |
5-10 |
1.0 |
660V |
50/60Hz |
DS-60 |
400/5A-1000/5A |
60x10mm |
10 |
1.0 |
660V |
50/60Hz |
DS-100 |
800/5A-3000/5A |
100x10mm |
5 |
1.0 |
660V |
50/60Hz |
Dimension of case (mm):
Model |
A |
B |
C |
D |
DS-20A |
56 |
30 |
63 |
80 |
DS-20 |
56 |
30 |
63 |
50 |
DS-30 |
56 |
30 |
63 |
50 |
DS-30 |
79 |
42 |
87 |
66 |
DS-40 |
79 |
42 |
87 |
66 |
DS-60 |
103 |
42 |
113 |
66 |
DS-100 |
151 |
42 |
166 |
69 |
Outline Drawing:

NSQ Current Transformers |
NSQ Series:
| Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: |
30A-3000A 5A, 1A BS7626, IEC44-1 0.66KV 50-60Hz 2.5VA, 5VA, 10VA, 15VA 0.5, 1.0, 3.0 Ith=60×Ih FS<5 |
![]() |
![]() |
![]() |
Technical data:
Model |
Primary/ secondary |
Busbar Hole Dimension |
Rated Burden (VA) |
class |
Rated Voltage |
Rated Frequency |
NSQ-30 |
30/5A-300/5A |
30×10mm |
2.5-5 |
0.5/1.0 |
0.72 |
50/60Hz |
NSQ-35 |
50/5A-400/5A |
35×10mm |
5 |
0.5/1.0 |
0.72 |
50/60Hz |
NSQ-40 |
100/5A-600/5A |
40×10mm |
10 |
0.5/1.0 |
0.72 |
50/60Hz |
NSQ-60 |
600/5A-1600/5A |
60×10mm |
15 |
0.5/1.0 |
0.72 |
50/60Hz |
NSQ-100 |
800/5A-3000/5A |
100×10mm |
15 |
0.5/1.0 |
0.72 |
50/60Hz |
Dimension of case (mm):
Model |
A |
B |
C |
D |
E |
F |
NSQ-30 |
30 |
78 |
46 |
95 |
112 |
70 |
NSQ-35 |
40 |
70 |
46 |
84 |
100 |
70 |
NSQ-40 |
45 |
80 |
46 |
87 |
104 |
70 |
NSQ-60 |
60 |
110 |
53 |
130 |
148 |
80 |
NSQ-100 |
100 |
155 |
53 |
174 |
191 |
80 |
Outline Drawing:

DX Current Transformers |
|
![]() |
![]() |
![]() |
![]() |
DX Series:
Model DX-20, DX-30, DX-40 are available for connecting with cable, and also available for connecting with bus bar.
| Maximum voltage: Frequency: Class: Short-time thermal current: Mounting methods: Window dimensions : |
0.66KV 50-60Hz 1.0 Ith=60Ih either by din rail (35mm) or by screws diameter 22mm (DX-20, DX-20L) 31x10mm (DX-30, DX-30L) 41x10mm (DX-40) |
Technical data& Specification:
Model |
Primary/ secondary |
Busbar Hole Dimension (MM) |
Rated Burden (VA) |
Class |
Rated Voltage |
DX-20 |
50/5A-150/5A |
f=20mm |
1.5-2.5 |
1.0 |
660V |
DX-30 |
100/5A-500/5A |
30¡Á10mm |
1.5-2.5 |
1.0 |
660V |
DX-40 |
150/5A-1000/5A |
40¡Á10mm |
3-10 |
1.0 |
660V |
DX-20L |
50/5A-150/5A |
f=20mm |
1.5-2.5 |
1.0 |
660V |
DX-30L |
100/5A-500/5A |
30¡Á10mm |
1.5-2.5 |
1.0 |
660V |
Dimension of case (mm):
Model |
A |
B |
C |
D |
E |
DX-20 |
53 |
28 |
57 |
66 |
54 |
DX-30 |
53 |
28 |
57 |
66 |
54 |
DX-40 |
71 |
45 |
73 |
81 |
65 |
DX-20L |
53 |
28 |
57 |
66 |
54 |
DX-30L |
53 |
28 |
57 |
66 |
54 |
Outline Drawing:


CDS Current Transformers |
CDS SERIES:
Primary current:
Secondary approval:
Standard current:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security coefficient:
-High fire retardancy and security
-Wide range of sizes to accommodate all the existing installations
![]() |
![]() |
![]() |
![]() |
![]() |
Specification:
Model |
Primary / secondary (A) |
CDS-40 |
100/5, 150/5, 200/5, 250/5, 300/5, 400/5, 500/5, 600/5A |
CDS-60 |
300/5, 400/5, 500/5, 600/5, 750/5, 800/5, 1000/5, 1200/5A |
CDS-80 |
500/5, 600/5, 750/5, 800/5, 1000/5, 1200/5, 1500/5, 1600/5A |
CDS-100 |
600/5, 750/5, 800/5, 1000/5, 1200/5, 1500/5, 1600/5, 2000/5A, 2500/5, 3000/5A |
CDS-120 |
1000/5, 1200/5, 1500/5, 1600/5, 2000/5, 2500/5, 3000/5, 4000/5A, 5000/5 |
Dimension of case (mm):
| Model | Dimensions |
Busbar hole dimension |
Installation dimension |
|||
W |
H |
D |
A |
E |
M | |
DS-40 |
75 |
105 |
45 |
42 |
32 |
45 |
DS-60 |
98 |
116 |
45 |
62 |
32 |
42 |
DS-80 |
118 |
120 |
45 |
82 |
32 |
60 |
DS-100 |
140 |
130 |
49 |
102 |
32 |
80 |
DS-120 |
165 |
152 |
49 |
122 |
53 |
80 |
Outline Drawing:

RED & EMC Current Transformers |
RES Series:
Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: |
100/5-600/5 5A, 1A BS7626, IEC44-1 0.66kV 50/60Hz 2.5VA-15VA 0.5, 0.5s Ith=60XIh FS<5 |
Technical data:
Type |
A |
VA |
Class |
RED-40 |
100/5 |
2.5 |
1 |
150/5 |
2.5 |
1 |
|
200/5 |
5 |
1 |
|
250/5 |
5 |
1 |
|
300/5 |
10 |
1 |
|
400/5 |
10 |
1 |
|
500/5 |
10 |
1 |
|
600/5 |
10 |
1 |
Outline Drawing:
![]() |
Technical data:
Type |
Rated current(A) |
VA |
Class |
EMC-30 |
100/5 |
5 |
0.5 |
150/5 |
5 |
0.5 |
|
200/5 |
5 |
0.5 |
|
EMC-40 |
200/5 |
5 |
0.5 |
250/5 |
5 |
0.5 |
|
300/5 |
10 |
0.5 |
|
400/5 |
10 |
0.5 |
|
500/5 |
15 |
0.5 |
|
600/5 |
15 |
0.5 |
Dimension of case (mm):
Type |
A |
B |
C |
D |
E |
F |
G |
H |
EMC-30 |
80 |
108 |
44 |
63 |
77 |
31 |
26 |
11 |
EMC-40 |
80 |
108 |
44 |
63 |
77 |
41 |
31 |
11 |
Outline Drawing:

MR Current Transformers |
![]() |
![]() |
Specification
Class:0.5 1.0 3.0
Type |
Current |
ID(mm) |
OD(mm) |
TD(mm) |
MR-28 |
30/5A-60/5A |
28 |
70 |
40 |
MR-42 |
100/5A-250/5A |
42 |
80 |
30 |
MR-45 |
300/5A |
45 |
80 |
30 |
MR-60 |
400/5A |
60 |
100 |
30 |
MR-60 |
400/5A 600/5A |
60 |
100 |
30 |
MR-85 |
800/5A-1600/5 |
85 |
120 |
20 |
MR-125 |
2000/A-5000/5 |
125 |
165 |
20 |
Outline Drawing:

PR Current Transformers |
PR Series:
Protective current transformers are required to operate over a range of current many times the circuit rating and is frequently subjected to conditions greatly exceeding those which it would be subjected to as a measuring current transformer. When a current transformer is used to energize a protective relay, it must maintain its characteristic ratio up to some multiple of its rated current. This multiple, may be 5, 10, 20 or some even higher value and is know as the "Accuracy Limit Factor"(ALF). Therefore, the selection of Protective Current Transformers in relation to accuracy class and ALF require a close examination of relay characteristic and circuit conditions which includes the relay burden and the pilot wire lead burden.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Dimensions (mm):
Spec. |
60/5A |
100/5A |
150/5A |
200/5A |
250/5A |
300/5A |
400/5A |
500/5A |
600/5A |
OD |
100 |
100 |
100 |
100 |
96 |
96 |
96 |
100 |
100 |
ID |
34 |
34 |
34 |
34 |
34 |
34 |
34 |
60 |
65 |
HT |
148 |
98 |
68 |
58 |
68 |
68 |
68 |
48 |
58 |
CI: 50P5 15VA
Spec. |
100 /5A |
150 /5A |
200 /5A |
250 /5A |
300 /5A |
400 /5A |
500 /5A |
600 /5A |
800 /5A |
1000 /5A |
1200 /5A |
1600 /5A |
2000 /5A |
2500 /5A |
3000 /5A |
3500 /5A |
4000 /5A |
5000 /5A |
OD |
100 |
100 |
100 |
96 |
96 |
96 |
102 |
110 |
120 |
120 |
123 |
123 |
123 |
178 |
178 |
182 |
182 |
184 |
ID |
34 |
34 |
34 |
45 |
45 |
45 |
62 |
68 |
62 |
85 |
82 |
82 |
125 |
125 |
125 |
120 |
120 |
118 |
HT |
180 |
130 |
110 |
110 |
110 |
90 |
110 |
88 |
22 |
68 |
60 |
68 |
40 |
40 |
40 |
35 |
35 |
38 |
CI: 10P10
| Spec. | 100 /5A |
150 /5A |
200 /5A |
300 /5A |
400 /5A |
500 /5A |
600 /5A |
800 /5A |
1000 /5A |
1200 /5A |
1600 /5A |
2000 /5A |
2500 /5A |
3000 /5A |
OD |
100 |
100 |
100 |
96 |
96 |
102 |
110 |
120 |
120 |
123 |
123 |
178 |
178 |
178 |
ID |
34 |
34 |
34 |
45 |
60 |
60 |
68 |
62 |
85 |
82 |
82 |
125 |
125 |
125 |
HT |
168 |
108 |
88 |
108 |
108 |
88 |
88 |
22 |
58 |
60 |
50 |
38 |
38 |
38 |
RCT Current Transformers |
RCT Series:
| Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: : |
30A-3000A 5A, 1A IEC44-1 0.66KV 50-60Hz 15VA 1.0 Ith=60xIh FS<5 |
![]() |
![]() |
![]() |
![]() |
![]() |
Specification:
Model |
Primary / secondary (A) |
RCT-25 |
15/5, 200/5, 30/5, 40/5, 50/5, 60/5, 75/5, 100/5A |
RCT-35 |
30/5, 50/5, 60/5, 80/5, 100/5, 120/5, 150/5, 200/5A, 250/5, 300/5 |
RCT-60 |
300/5, 400/5, 500/5, 600/5, 800/5, 1000/5, 1200/5 |
RCT-90 |
800/5, 1000/5, 1200/5, 1500/5, 1600/5 |
RCT-110 |
1000/5, 1200/5, 1500/5, 1600/5, 2000/5, 2500/5, 3000/5 |
Dimension of case (mm):
Model |
RCT-25 |
RCT-35 |
RCT-60 |
RCT-90 |
RCT-110 |
A |
93 |
93 |
93 |
93 |
102 |
B |
78 |
78 |
78 |
78 |
86 |
C |
25 |
32 |
60 |
90 |
111 |
D |
78 |
78 |
104 |
136 |
157 |
E |
2 |
2 |
2 |
2 |
2 |
F |
55 |
55 |
41 |
41 |
52 |
G |
9 |
9 |
9 |
9 |
9 |
Outline Drawing:

D363 & D364 Current Transformers |
![]() |
||
| Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: |
3 X 40A-600A 5A, 1A BS7626, IEC44-1, IEC185 0.72/3KV 50-60Hz 1.25VA-5VA 0.5, 1.0, 3.0 Ith=60 X Ih FS<5 |
|
Technical data:
Model |
Primary/ secondary |
Busbar Hole Dimension |
Rated Burden (VA) |
class |
Rated Voltage |
Rated Frequency |
D363 |
3 X 40/5A-500/5A |
3 X 27mm |
1.25-5VA |
1/3 |
0.72 |
50/60Hz |
D364 |
3 X 300/5A-600/5A |
3 X 27mm |
2.5-5VA |
1/3 |
0.72 |
50/60Hz |
Dimension of case (mm):
Model |
A |
B |
C |
D |
E |
F |
G |
D363 |
185 |
84 |
27 |
75 |
87 |
61 |
41 |
D364 |
185 |
84 |
37 |
37 |
87 |
61 |
41 |
Outline drawing:
SFT Current Transformers |
![]() |
![]() |
![]() |
Technical data:
Model |
Primary/ secondary |
Busbar Hole Dimension |
Rated Burden (VA) |
class |
Rated Voltage |
Rated Frequency |
2SFT |
30/5A-300/5A |
30 |
2.5-5VA |
1.0 |
0.72 |
50/60Hz |
5SFT |
100/5A-800/5A |
40 |
5-10VA |
1.0 |
0.72 |
50/60Hz |
19SHT |
800/5A-3000/5A |
110 |
15VA |
1.0 |
0.72 |
50/60Hz |
Dimension of case (mm):
Model |
A |
B |
C |
D |
E |
F |
2SFT-500 |
61 |
68 |
23 |
30 |
51 |
45 |
5SFT-601 |
91 |
96 |
72 |
40 |
55 |
70 |
19SHT-152 |
165 |
165 |
90 |
110 |
30 |
127 |
Outline Drawing: