Limit Switches
![]() TZ-8 Limit Switch |
![]() CSA Limit Switch |
![]() CLS Limit Switch |
![]() CWL Limit Switch |
![]() CHL Limit Switch |
![]() TZ-6 Limit Switch |
![]() CZ-3 Compact Prewired Limit Switch |
![]() CZ-93 Safety Key Interlock Switch |
||||
TZ-8 Limit Switch |
|
Features
![]() |
Rated Voltage |
Noninductive Load (A) | Inductive Load (A) | ||||||
| Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC 250VAC 500VAC |
5 5 |
5 5 |
1.5 1 |
0.7 0.5 |
3 3 |
3 3 |
2 1.5 |
1 0.8 |
| 8VDC 14VDC 30VDC 125VDC 250VDC |
5 5 5 0.4 0.2 |
5 5 5 0.4 0.2 |
3 3 3 |
3 3 3 |
5 4 4 |
4 4 4 |
3 3 3 |
3 3 3 |
| Inrush Current | N.C: below 24A, N.O: below 12A | |||||||
-
NOTES:
- 1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
- 2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
Operation speed |
0.5mm-50cm/sec |
| Operating frequency | Mechanical: 120 operations/minute, Electrical: 30 operations/minute |
| Contact resistance | 25mΩ max. (initial value) |
| Insulation resistance | 100mΩ min. (at 500VDC) |
| Dielectric strength | 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity |
| 1500VAC, 50/60 HZ for 1 minute between currentcarrying and non-current-carrying metal parts |
|
| 1500VAC, 50/60 HZ for 1 minute between each terminal and ground | |
| Vibration | 10-55HZ,1.5mm double amplitude |
| Shock | Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30G'S) |
| Ambient temperature | -5℃ to +65℃ |
| Humidity | <95% RH |
| Life | Mechanical: 10,000,000 operations above Electrical: 500,000 operations above |
| Weight | About 130 to 190g |
| Degree of protection | IP65 |
Models |
TZ-8104 | TZ-8108 | TZ-8107 | TZ-8111 | TZ-8112/8122 | TZ-8166/8167/8168/8169 |
| OF Max. | 750g | 750g | 750g | 900g | 900g | 150g |
| RF Min. | 100g | 100g | 100g | 150g | 150g | - |
| PT Max. | 20º | 20 º | 20 º | 1.5mm | 1.5mm | 30mm |
| OT Min. | 50 º | 50 º | 50 º | 4mm | 4mm | - |
| MD Max. | 12 º | 12 º | 12 º | 1mm | 1mm | - |
| OP | - | - | - | 26 ± 0.8mm | 37 ± 0.8mm | - |
CSA Limit Switch |
![]() |
Features
|
| Model | CSA | CSA-001 | CSA-003 | CSA-012 | CSA-021 | CSA-031 | CSA-061 | CSA-071 | CSA-081 |
| Operating force | OF Max. | 800g | 800g | 800g | 400g-cm | 400g-cm | 150g | 150g | 150g |
| Release force | RF Min. | 400g | 400g | 400g | 100g-cm | 100g-cm | 50g | 50g | 50g |
| Pre-travel | PT Max. | 1.8mm | 1.8mm | 1.8mm | 20 º | 20 º | 30mm | 30mm | 30mm |
| Travel position | TP ± 10% | 2.0mm | 2.0mm | 2.0mm | 22.5 º | 22.5 º | 22.5 º | 22.5 º | 22.5 º |
| Movement differential | MD Max. | 1.2mm | 1.2mm | 1.2mm | 10 º | 10 º | 14 º | 14 º | 14 º |
| Over travel | OT Min. | 4.0mm | 4.0mm | 4.0mm | 75 º | 75 º | 20mm | 20mm | 20mm |
| Total travel | TT Min. | 5.8mm | 5.8mm | 5.8mm | 95 º | 95 º | 50mm | 50mm | 50mm |
| Rotary indexing | 22.5 º | 22.5 º |
| Double Break Mechanism | INO+INC Force Break snap action |
| Rated Voltage/Current | 10(4)A, 125, 250VAC/6(2)A, 380VAC For inductance Load, CosØ =0.4 |
| Contact Resistance | 25mΩ max. (initial value) |
| Insulation Resistance | 100mΩ min. (at 500VDC) |
| Dielectric Strength | 1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity |
| 1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts | |
| 1500VAC, 50/60 HZ for 1 minute between each terminal and ground | |
| Electrical Life | 500,000 at 10A 250VAC Resistive |
| Mechanical Life | 10, 000, 000 operations min. (under rated conditions) |
| Operating Speed | 5mm/s to 0.5m/s |
| Degree of Protection | IP65 |
| Ambient Temperature Rised | Max 30℃ over ambient temperature at rated voltage/current |
| Conformed Standards | Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660 |
| Operating Temperature | -5℃ ~+65℃ (with no icing) |
| Storage Temperature | -5℃ ~+65℃ (with no icing) |
| Ambient Operating Humidity | 95 RH Max. |
| Shock Resistance | Mechanical durable: 1000m/s2 min. |
| Malfunction: 300m/s2 min. | |
| Vibration Frequency | Malfunction: 10 to 55HZ, 1.5mm double amplitude |
| Terminal Screw Torsional Force | 6-8 kgf-cm |
| Other Screw Torsional Force | Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm |
| Bare Wire Diameter | Ø2 Max |
| Cable Diameter | Ø12 Max(IP 65 if use cable 8-9) |
CLS Limit Switch |
|
Features
![]() |
| Model | CLS | 101 301 |
101 303 |
111 311 |
121 321 |
127 327 |
131 331 |
161 361 |
171 371 |
181 381 |
191 391 |
| Operating force | OF Max. | 700g | 700g | 700g | 500g | 700g | 500g-cm | 100g | 100g | 100g | 500g-cm |
| Release force | RF Min. | 200g | 200g | 200g | 100g-cm | 200g | 100g-cm | 40g | 40g | 40g | 100g-cm |
| Pre-travel | PT Max. | 1.8mm | 1.8mm | 1.8mm | 20 º | 1.8mm | 20 º | 30mm | 30mm | 30mm | 20 º |
| Tripping position | TP ± 10% | 2.0mm | 2.0mm | 2.0mm | 22.5 º | 2.0mm | 22.5 º | 22.5 º | 22.5 º | 22.5 º | 22.5 º |
| Movement differential | MD Max. | 1.2mm | 1.2mm | 1.2mm | 10 º | 1.2mm | 10 º | 14 º | 14 º | 14 º | 10 º |
| Over travel | OT Min. | 4.0mm | 4.0mm | 4.0mm | 75 º | 4.0mm | 75 º | 20mm | 20mm | 20mm | 75 º |
| Total travel | TT Min. | 5.8mm | 5.8mm | 5.8mm | 95 º | 5.8mm | 95 º | 50mm | 50mm | 50mm | 95 º |
| Rotary indexing | 22.5 º | 22.5 º | 22.5 º |
| Double Break Mechanism | INO+INC Force Break snap action |
| Rated Voltage/Current | 10(4)A, 125, 250VAC/6(2)A, 380VAC For inductance Load, CosØ =0.4 |
| Contact Resistance | 25mΩ max. (initial value) |
| Insulation Resistance | 100mΩ min. (at 500VDC) |
| Dielectric Strength | 1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity |
| 1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts | |
| 1500VAC, 50/60 HZ for 1 minute between each terminal and ground | |
| Electrical Life | 500,000 at 10A 250VAC Resistive |
| Mechanical Life | 10, 000, 000 operations min. (under rated conditions) |
| Operating Speed | 5mm/s to 0.5m/s |
| Degree of Protection | IP65 |
| Ambient Temperature Rised | Max 30℃ over ambient temperature at rated voltage/current |
| Conformed Standards | Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660 |
| Operating Temperature | -5℃ ~+65℃ (with no icing) |
| Storage Temperature | -5℃ ~+65℃ (with no icing) |
| Ambient Operating Humidity | 95 RH Max. |
| Shock Resistance | Mechanical durable: 1000m/s2 min. |
| Malfunction: 300m/s2 min. | |
| Vibration Frequency | Malfunction: 10 to 55HZ, 1.5mm double amplitude |
| Terminal Screw Torsional Force | 6-8 kgf-cm |
| Other Screw Torsional Force | Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm |
| Bare Wire Diameter | Ø2 Max |
| Cable Diameter | Ø12 Max |
CWL Limit Switch |
|
Features
![]() |
| Rated Voltage | Noninductive Load (A) | Inductive Load (A) | ||||||
| Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC 250VAC 480VAC 600VAC |
10 5 3 1 |
3 2 1.5 1 |
1.5 1 0.8 0.5 |
10 5 3 1.5 |
5 3 1.5 1 |
2.0 1.0 0.8 0.5 |
||
| 8VDC 14VDC 30VDC 125VDC 250VDC |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
3 3 3 0.2 0.1 |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
|||
-
NOTES:
- 1. Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
- 2. Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
| Operation speed | 1mm-2m/sec |
| Operating frequency | Mechanical: 120 operations/minute, Electrical: 30 operations/minute |
| Contact resistance | 25mΩ max. (initial value) |
| Insulation resistance | 100mΩ min. (at 500VDC) |
| Dielectric strength | 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity |
| 1500VAC, 50/60 HZ for 1 minute between currentcarrying and non-current-carrying metal parts |
|
| 1500VAC, 50/60 HZ for 1 minute between each terminal and ground | |
| Vibration | 10-55HZ,1.5mm double amplitude |
| Shock | Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30G'S) |
| Ambient temperature | -10℃ to +80℃ |
| Humidity | <95% RH |
| Life | Mechanical: 15,000,000 operations above (under rated OT) Electrical: 500,000 operations above |
| Weight | About 275g |
| Degree of protection | IP67 |
| Models | CWLCA2-2 | CWLD2 | CWLNJ | CWLNJ-S2 | CWLCA12-2-Q | CWLCL | CWLCA32-41 | CWLD | CWLNJ-2 | CWLNJ-30 | CWLD1 |
| OF Max. | 1360g | 2720g | 150g | 29g | 1360g | 142g | 1200g | 2720g | 120g | 80g | 2720g |
| RF Min. | 227g | 910g | - | - | 227g | 28g | - | 910g | - | - | 910g |
| PT Max. | 20 º | 1.7mm | 28mm | 28mm | 20 º | 20 º | 55 º | 1.7mm | 28mm | 28mm | 1.7mm |
| OT Min. | 30 º | 5.6mm | - | - | 30 º | 30 º | 35 º | 6.4mm | - | - | 5.6mm |
| MD Max. | 12 º | 1mm | - | - | 12 º | 12 º | - | 1mm | - | - | 1mm |
| TF Max. | 2720g | - | - | - | 2720g | 200g | - | - | - | - | 2720g |
| TT Min. | 50 º | 6.5±0.8mm | - | - | 50 º | 50 º | OP:90±10 º | OP:34±2.8mm | - | - | 6.5±0.8mm |
CHL Limit Switch |
|
Features
![]() |
| Models | CHL | 5000 | 5030 | 5050 | 5100 | 5200 | 5220 | 5300 | 5330 | 5381 | 5391 |
| Operating force | OF Max. | 750g-cm | 750g-cm | 750g-cm | 750g-cm | 900g-cm | 900g-cm | 150g | 150g | 150g | 550g-cm |
| Release force | RF Min. | 100g-cm | 100g-cm | 100g-cm | 200g | 200g | 200g | 30g | 30g | 30g | 100g-cm |
| Pre-travel | PT Max. | 20 º | 20 º | 20 º | 1.8mm | 1.8mm | 1.8mm | 30mm | 30mm | 30mm | 20 º |
| Tripping position | TP ± 10% | 22.5 º | 22.5 º | 22.5 º | 2.0mm | 2.0mm | 2.0mm | 22.5 º | 22.5 º | 22.5 º | 22.5 º |
| Movement differential | MD Max. | 10 º | 10 º | 10 º | 1.2mm | 1.2mm | 1.2mm | 14 º | 14 º | 14 º | 14 º |
| Over travel | OT Min. | 75 º | 75 º | 75 º | 4.0mm | 4.0mm | 4.0mm | 20mm | 20mm | 20mm | 75 º |
| Total travel | TT Min. | 95 º | 95 º | 95 º | 5.8mm | 5.8mm | 5.8mm | 50mm | 50mm | 50mm | 95 º |
| Double Break Mechanism | INO+INC Force Break snap action |
| Rated Voltage/Current | 10(4)A, 125, 250VAC/6(2)A, 380VAC For inductance Load, CosØ =0.4 |
| Contact Resistance | 25mΩ max. (initial value) |
| Insulation Resistance | 100mΩ min. (at 500VDC) |
| Dielectric Strength | 1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity |
| 1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts | |
| 1500VAC, 50/60 HZ for 1 minute between each terminal and ground | |
| Electrical Life | 500,000 at 10A 250VAC Resistive |
| Mechanical Life | 10, 000, 000 operations min. (under rated conditions) |
| Operating Speed | 5mm/s to 0.5m/s |
| Degree of Protection | IP65 |
| Ambient Temperature Rised | Max 30℃ over ambient temperature at rated voltage/current |
| Conformed Standards | Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660 |
| Operating Temperature | -5℃ ~+65℃ (with no icing) |
| Storage Temperature | -5℃ ~+65℃ (with no icing) |
| Ambient Operating Humidity | 95 RH Max. |
| Shock Resistance | Mechanical durable: 1000m/s2 min. |
| Malfunction: 300m/s2 min. | |
| Vibration Frequency | Malfunction: 10 to 55HZ, 1.5mm double amplitude |
| Terminal Screw Torsional Force | 6-8 kgf-cm |
| Other Screw Torsional Force | Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm |
| Bare Wire Diameter | Ø2 Max |
| Cable Diameter | Ø12 Max(IP 65 if use cable 8-9) |
TZ-6 Limit Switch |
|
Features
![]() |
| Models | TZ-6001 | TZ-6002 | TZ-6003 | TZ-6004 | TZ-6043 | TZ-6101 | TZ-6102 | TZ-6103 | TZ-6104 | TZ-6143 |
| OF Max. | 250~350g | 250~350g | 570g | 570g | 800g | 500g | 640g | 640g | ||
| RF Min. | 114g | 114g | 170g | 170g | 240g | 100g | 230g | 230g | ||
| PT Max. | 0.4mm | 0.5mm | 4mm | 4mm | 2mm | 1mm | 5mm | 5mm | ||
| OT Min. | 5.5mm | 3.6mm | 6mm | 6mm | 5mm | 3.5mm | 6mm | 6mm | ||
| MD Max. | 0.05mm | 0.05mm | 0.4mm | 0.4mm | 0.1mm | 0.12mm | 0.4mm | 0.4mm | ||
| OP | 38.2±0.8mm | 49.7 ±1mm | 45.8 ± 0.8mm | 49.7 ±0.8mm | - | |||||
CZ-3 Compact Prewired Limit Switch |
|
Specifications
|
| Rated Voltage (V) | Noninductive Load (A) | Inductive Load (A) | ||||||
| Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC 250VAC |
5(0.1) 3 |
1.5 1 |
0.7 0.5 |
3 2 |
2 1.5 |
1.3 0.8 |
||
| 8VDC 14VDC 30VDC 125VDC 250VDC |
5(0.1) 5(0.1) 4(0.1) 0.4 0.2 |
2 2 2 0.05 0.03 |
5 4 3 0.4 0.2 |
4 4 3 0.4 0.2 |
3 3 3 0.05 0.03 |
|||
Rating |
5A 125V, 3A 250VAC |
| Operating speed | 1mm-1m/s |
| Operating frequency | Mechanical: 120 operations/min. |
| Electrical: 30 operations/min. | |
| Contact resistance | 15mΩ max. (initial value) |
| Insulation resistance | 100mΩ min. (at 500VDC) |
| Dielectric strength | 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity |
| 1500VAC, 50/60 HZ for 1 minute between currentcarrying and non-current-carrying metal parts |
|
| 1500VAC, 50/60 HZ for 1 minute between each terminal and ground | |
| Vibration frequency | 10-55HZ,1.5mm double amplitude |
| Shock | Mechanical: 1, 000m/Sec2 (about 100G'S) Electrical: 500m/Sec2 (about 50G'S) |
| Ambient temperature | -10℃ to +70℃ |
| Humidity | <95% RH |
| Life | Mechanical: 10,000,000 operations min. Electrical: 200,000 operations min. |
| Degree of protection | IEC: IP 67 |
| Weight | Approx. 360g (cable length 3m) |
| Approx. 540g (cable length 5m) |
Models |
CZ-3101 | CZ-3102 | CZ-3103 | CZ-3104 | CZ-3110 | CZ-3111 | CZ-3112 | CZ-3113 | CZ-3169 |
| OF Max. | 1200gf (11.77N) |
1200g f(11.77N) |
1200gf (11.77N) |
580gf (5.69N) |
1200gf (11.77N) |
1800gf (17.65N) |
1800gf (17.65N) |
1800gf (17.65N) |
150gf (1.47N) |
| RF Min. | 450gf (4.41N) |
450gf (4.41N) |
450gf (4.41N) |
150gf (1.47N) |
450gf (4.41N) |
450gf (4.41N) |
450gf (4.41N) |
450gf (4.41N) |
- |
| PT Max. | 1.8mm | 1.8mm | 1.8mm | 25 | 1.8mm | 1.8mm | 1.8mm | 1.8mm | 15 º |
| OT Min. | 3mm | 3mm | 3mm | 40 | 3mm | 3mm | 3mm | 3mm | - |
| MD Max. | 0.2mm | 0.2mm | 0.2mm | 3 | 0.2mm | 0.2mm | 0.2mm | 0.2mm | - |
| OP | 15.7 ± 1mm | 28.5 ±1mm | 28.5 ±1mm | - | 28.5± 1mm | 24.9 ±1mm | 34.3 ±1mm | 34.3 ±1mm | - |
| Fastening of the switch cable The switch bodies are filled with resin for sealing purposes. To avoid stressing the cable and switch body, fasten the switch at 5 cm or farther away from the switch body, should the wire be bent, the bending radius shall be at least 45mm. |
Installation The service life and accuracy of switches will be effected bythe shape of actuator operation frequency & over travel. So theangular of the fixing level should be about 30, the surface finishof the fixing level should be over, the hardness is from HV400~500.When installing, the position of the concave part should be abovethe standard panel |
|||||||||
![]() |
![]() |
|||||||||
| Contact types | Switch bank mounting A maximum of six switches may be mounted together as a switch bank.During the installation,the convex part of the switch back.The mounting panel shall be 6mm or thicker. |
|||||||||
![]() |
![]() |
|||||||||
| Mounting Recommended tightening torque according to the follwing form. |
Mounting holes Mount the switch body to a rigid mounting panel using two M5 screws. |
|||||||||
|
![]() |
CZ-93 Safety Key Interlock Switch |
|
Model designations
|
| Rated Voltage (V) | Noninductive Load (A) | Inductive Load (A) | ||||||
| Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC 250VAC 400VAC |
10 10 10 |
3 2 1.5 |
1.5 1 0.8 |
10 10 3 |
5 3 1.5 |
2.5 1.5 0.8 |
||
| 8VDC 14VDC 30VDC 125VDC 250VDC |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
3 3 3 0.2 0.1 |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
|||
| Rating | 3A 240VAC (A300) |
| Operating speed | 0.1m-0.5m/s |
| Operating frequency | 30 operations/minute |
| Contact resistance | 25mΩ max. (initial value) |
| Insulation resistance | 100mΩ min. (at 500VDC) |
| Rated insulation voltage (UI) | 400V |
| Dielectric strength | AC2500V/Umip 4KV |
| Vibration frequency | 10-55HZ,1.5mm double amplitude |
| Shock | Mechanical: Approx. 1, 000m/Sec2 (about 100G'S) Electrical: Approx. 300m/Sec2 (about 30G'S) |
| Ambient temperature | -30℃ to +70℃ |
| Humidity | <95% RH |
| Life | Mechanical: 10,000,000 operations above Electrical: 150,000 operations above |
| Degree of protection | IP65 (EN60947-5-1) |
| Short-circuit protective device | 10A fuse |
| Weight | Approx. 76g |
To prevent the wear and the space should be within 1mm between the key and middle of the insert hole.

When in use,there should put a plate on the top to prevent the key overinsert.To prevent nonmovement ,the space between the plate and the switch should be under 3 mm.

Required to have positive machine

When the contact block get fire,press on the middle of the key structure, the NC strict leaving structure can push the contact block a way cut off the movement.