Limit Switches

Porducts Information
TZ-8 Limit Switch
TZ-8 Limit Switch
CSA Limit Switch
CSA Limit Switch
CLS Limit Switch
CLS Limit Switch
CWL Limit Switch
CWL Limit Switch
CHL Limit Switch
CHL Limit Switch
TZ-6 Limit Switch
TZ-6 Limit Switch
CZ-3 Compact Prewired Limit Switch
CZ-3 Compact Prewired Limit Switch
CZ-93 Safety Key Interlock Switch
CZ-93 Safety Key Interlock Switch

TZ-8 Limit Switch

TZ-8 Limit Switch
Features
  • Double circuit type of limit switch
  • Highly rigid construction, consists of intensive plastic and aluminum cast (Head and cover snugly fit in box)
  • Small volume, water-proof and oil-proof construction
  • Built-in basic switch with double spring mechanism, longer mechanical life
  • Smooth operation with greater OT
  • Easy-to-wire circuit opening design
  • Wide varity of actuators, easily use
Contact Form
Ratings

Rated Voltage
Noninductive Load (A) Inductive Load (A)
Resistance Load Lamp Load Inductive Load Motor Load
NC NO NC NO NC NO NC NO
125VAC
250VAC
500VAC
5
5
5
5
1.5
1
0.7
0.5
3
3
3
3
2
1.5
1
0.8
8VDC
14VDC
30VDC
125VDC
250VDC
5
5
5
0.4
0.2
5
5
5
0.4
0.2
3
3
3
3
3
3
5
4
4
4
4
4
3
3
3
3
3
3
Inrush Current N.C: below 24A, N.O: below 12A
Characteristics

Operation speed
0.5mm-50cm/sec
Operating frequency Mechanical: 120 operations/minute, Electrical: 30 operations/minute
Contact resistance 25mΩ max. (initial value)
Insulation resistance 100mΩ min. (at 500VDC)
Dielectric strength 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between currentcarrying
and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
Vibration 10-55HZ,1.5mm double amplitude
Shock Mechanical durable: 1, 000m/Sec2 (about 100G'S)
Malfunction: 300m/Sec2 (about 30G'S)
Ambient temperature -5℃ to +65℃
Humidity <95% RH
Life Mechanical: 10,000,000 operations above
Electrical: 500,000 operations above
Weight About 130 to 190g
Degree of protection IP65
Operating characteristics

Models
TZ-8104 TZ-8108 TZ-8107 TZ-8111 TZ-8112/8122 TZ-8166/8167/8168/8169
OF Max. 750g 750g 750g 900g 900g 150g
RF Min. 100g 100g 100g 150g 150g -
PT Max. 20º 20 º 20 º 1.5mm 1.5mm 30mm
OT Min. 50 º 50 º 50 º 4mm 4mm -
MD Max. 12 º 12 º 12 º 1mm 1mm -
OP - - - 26 ± 0.8mm 37 ± 0.8mm -

CSA Limit Switch

CSA Limit Switch
Features
  • Strong metal outer shell, swing arm max. 95
  • Long life (20, 000, 000 mechanical operations)
  • Stainless steel idler wheel, punch and spring
  • Selective PG11 cable gland
Specifications
Model CSA CSA-001 CSA-003 CSA-012 CSA-021 CSA-031 CSA-061 CSA-071 CSA-081
Operating force OF Max. 800g 800g 800g 400g-cm 400g-cm 150g 150g 150g
Release force RF Min. 400g 400g 400g 100g-cm 100g-cm 50g 50g 50g
Pre-travel PT Max. 1.8mm 1.8mm 1.8mm 20 º 20 º 30mm 30mm 30mm
Travel position TP ± 10% 2.0mm 2.0mm 2.0mm 22.5 º 22.5 º 22.5 º 22.5 º 22.5 º
Movement differential MD Max. 1.2mm 1.2mm 1.2mm 10 º 10 º 14 º 14 º 14 º
Over travel OT Min. 4.0mm 4.0mm 4.0mm 75 º 75 º 20mm 20mm 20mm
Total travel TT Min. 5.8mm 5.8mm 5.8mm 95 º 95 º 50mm 50mm 50mm
Rotary indexing         22.5 º 22.5 º      
Characteristics
Double Break Mechanism INO+INC Force Break snap action
Rated Voltage/Current 10(4)A, 125, 250VAC/6(2)A, 380VAC For inductance Load, CosØ =0.4
Contact Resistance 25mΩ max. (initial value)
Insulation Resistance 100mΩ min. (at 500VDC)
Dielectric Strength 1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
Electrical Life 500,000 at 10A 250VAC Resistive
Mechanical Life 10, 000, 000 operations min. (under rated conditions)
Operating Speed 5mm/s to 0.5m/s
Degree of Protection IP65
Ambient Temperature Rised Max 30℃ over ambient temperature at rated voltage/current
Conformed Standards Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660
Operating Temperature -5℃ ~+65℃ (with no icing)
Storage Temperature -5℃ ~+65℃ (with no icing)
Ambient Operating Humidity 95 RH Max.
Shock Resistance Mechanical durable: 1000m/s2 min.
Malfunction: 300m/s2 min.
Vibration Frequency Malfunction: 10 to 55HZ, 1.5mm double amplitude
Terminal Screw Torsional Force 6-8 kgf-cm
Other Screw Torsional Force Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm
Bare Wire Diameter Ø2 Max
Cable Diameter Ø12 Max(IP 65 if use cable 8-9)

CLS Limit Switch

CLS Limit Switch
Features
  • Economical & plastic type
  • Stainless steel roller, punch and spring
  • Swing amplitude, extra large ± 95°
  • PG13.5 cable gland that can be equipped.
Electrical life
Specification
Model CLS 101
301
101
303
111
311
121
321
127
327
131
331
161
361
171
371
181
381
191
391
Operating force OF Max. 700g 700g 700g 500g 700g 500g-cm 100g 100g 100g 500g-cm
Release force RF Min. 200g 200g 200g 100g-cm 200g 100g-cm 40g 40g 40g 100g-cm
Pre-travel PT Max. 1.8mm 1.8mm 1.8mm 20 º 1.8mm 20 º 30mm 30mm 30mm 20 º
Tripping position TP ± 10% 2.0mm 2.0mm 2.0mm 22.5 º 2.0mm 22.5 º 22.5 º 22.5 º 22.5 º 22.5 º
Movement differential MD Max. 1.2mm 1.2mm 1.2mm 10 º 1.2mm 10 º 14 º 14 º 14 º 10 º
Over travel OT Min. 4.0mm 4.0mm 4.0mm 75 º 4.0mm 75 º 20mm 20mm 20mm 75 º
Total travel TT Min. 5.8mm 5.8mm 5.8mm 95 º 5.8mm 95 º 50mm 50mm 50mm 95 º
Rotary indexing   22.5 º 22.5 º 22.5 º
Characteristics
Double Break Mechanism INO+INC Force Break snap action
Rated Voltage/Current 10(4)A, 125, 250VAC/6(2)A, 380VAC  For inductance Load, CosØ =0.4
Contact Resistance 25mΩ max. (initial value)
Insulation Resistance 100mΩ min. (at 500VDC)
Dielectric Strength 1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
Electrical Life 500,000 at 10A 250VAC Resistive
Mechanical Life 10, 000, 000 operations min. (under rated conditions)
Operating Speed 5mm/s to 0.5m/s
Degree of Protection IP65
Ambient Temperature Rised Max 30℃ over ambient temperature at rated voltage/current
Conformed Standards Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660
Operating Temperature -5℃ ~+65℃ (with no icing)
Storage Temperature -5℃ ~+65℃ (with no icing)
Ambient Operating Humidity 95 RH Max.
Shock Resistance Mechanical durable: 1000m/s2 min.
Malfunction: 300m/s2 min.
Vibration Frequency Malfunction: 10 to 55HZ, 1.5mm double amplitude
Terminal Screw Torsional Force 6-8 kgf-cm
Other Screw Torsional Force Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm
Bare Wire Diameter Ø2 Max
Cable Diameter Ø12 Max

CWL Limit Switch

CWL Limit Switch
Features
  • Double-circuit type of limit switch, is widely used
  • With strong aluminum cast outer shell
  • High mechanical strength
  • Water-proof, oil-proof construction
  • Structure preventing oil, water and pressure
  • Indicating plate with setting position is installed in it, so it is easy to maintain
  • Various of actuators is taken convenience for using
  • Built-in contact stand has double-spring, so it has long mechanical life
Contact Form
Ratings
Rated Voltage Noninductive Load (A) Inductive Load (A)
Resistance Load Lamp Load Inductive Load Motor Load
NC NO NC NO NC NO NC NO
125VAC
250VAC
480VAC
600VAC
10
5
3
1
3
2
1.5
1
1.5
1
0.8
0.5
10
5
3
1.5
5
3
1.5
1
2.0
1.0
0.8
0.5
8VDC
14VDC
30VDC
125VDC
250VDC
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
Characteristics
Operation speed 1mm-2m/sec
Operating frequency Mechanical: 120 operations/minute, Electrical: 30 operations/minute
Contact resistance 25mΩ max. (initial value)
Insulation resistance 100mΩ min. (at 500VDC)
Dielectric strength 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between currentcarrying
and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
Vibration 10-55HZ,1.5mm double amplitude
Shock Mechanical durable: 1, 000m/Sec2 (about 100G'S)
Malfunction: 300m/Sec2 (about 30G'S)
Ambient temperature -10℃ to +80℃
Humidity <95% RH
Life Mechanical: 15,000,000 operations above (under rated OT)
Electrical: 500,000 operations above
Weight About 275g
Degree of protection IP67
Operating characteristics
Models CWLCA2-2 CWLD2 CWLNJ CWLNJ-S2 CWLCA12-2-Q CWLCL CWLCA32-41 CWLD CWLNJ-2 CWLNJ-30 CWLD1
OF Max. 1360g 2720g 150g 29g 1360g 142g 1200g 2720g 120g 80g 2720g
RF Min. 227g 910g - - 227g 28g - 910g - - 910g
PT Max. 20 º 1.7mm 28mm 28mm 20 º 20 º 55 º 1.7mm 28mm 28mm 1.7mm
OT Min. 30 º 5.6mm - - 30 º 30 º 35 º 6.4mm - - 5.6mm
MD Max. 12 º 1mm - - 12 º 12 º - 1mm - - 1mm
TF Max. 2720g - - - 2720g 200g - - - - 2720g
TT Min. 50 º 6.5±0.8mm - - 50 º 50 º OP:90±10 º OP:34±2.8mm - - 6.5±0.8mm

CHL Limit Switch

CHL Limit Switch
Features
  • Metallic bottom shell
  • Stainless steel roller, punch and spring
  • Strong electric property 10A, 250V, for 500,000 times
Electrical life
Specification
Models CHL 5000 5030 5050 5100 5200 5220 5300 5330 5381 5391
Operating force OF Max. 750g-cm 750g-cm 750g-cm 750g-cm 900g-cm 900g-cm 150g 150g 150g 550g-cm
Release force RF Min. 100g-cm 100g-cm 100g-cm 200g 200g 200g 30g 30g 30g 100g-cm
Pre-travel PT Max. 20 º 20 º 20 º 1.8mm 1.8mm 1.8mm 30mm 30mm 30mm 20 º
Tripping position TP ± 10% 22.5 º 22.5 º 22.5 º 2.0mm 2.0mm 2.0mm 22.5 º 22.5 º 22.5 º 22.5 º
Movement differential MD Max. 10 º 10 º 10 º 1.2mm 1.2mm 1.2mm 14 º 14 º 14 º 14 º
Over travel OT Min. 75 º 75 º 75 º 4.0mm 4.0mm 4.0mm 20mm 20mm 20mm 75 º
Total travel TT Min. 95 º 95 º 95 º 5.8mm 5.8mm 5.8mm 50mm 50mm 50mm 95 º
Characteristics
Double Break Mechanism INO+INC Force Break snap action
Rated Voltage/Current 10(4)A, 125, 250VAC/6(2)A, 380VAC For inductance Load, CosØ =0.4
Contact Resistance 25mΩ max. (initial value)
Insulation Resistance 100mΩ min. (at 500VDC)
Dielectric Strength 1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
Electrical Life 500,000 at 10A 250VAC Resistive
Mechanical Life 10, 000, 000 operations min. (under rated conditions)
Operating Speed 5mm/s to 0.5m/s
Degree of Protection IP65
Ambient Temperature Rised Max 30℃ over ambient temperature at rated voltage/current
Conformed Standards Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660
Operating Temperature -5℃ ~+65℃ (with no icing)
Storage Temperature -5℃ ~+65℃ (with no icing)
Ambient Operating Humidity 95 RH Max.
Shock Resistance Mechanical durable: 1000m/s2 min.
Malfunction: 300m/s2 min.
Vibration Frequency Malfunction: 10 to 55HZ, 1.5mm double amplitude
Terminal Screw Torsional Force 6-8 kgf-cm
Other Screw Torsional Force Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm
Bare Wire Diameter Ø2 Max
Cable Diameter Ø12 Max(IP 65 if use cable 8-9)

TZ-6 Limit Switch

TZ-6 Limit Switch
Features
  • Built-in CM miniature limit switch, strong aluminum cast shell, design for water-proof and oil-proof
  • It is the same as CM micro switch in the rated value and characteristics
  • Various of actuators that are taken convenience for using
  • Each switch is equipped with cable fixator, including rubber boot, metallic washer, plastic screw nut
Contact Form
Operating characteristics
Models TZ-6001 TZ-6002 TZ-6003 TZ-6004 TZ-6043 TZ-6101 TZ-6102 TZ-6103 TZ-6104 TZ-6143
OF Max. 250~350g 250~350g 570g 570g 800g 500g 640g 640g
RF Min. 114g 114g 170g 170g 240g 100g 230g 230g
PT Max. 0.4mm 0.5mm 4mm 4mm 2mm 1mm 5mm 5mm
OT Min. 5.5mm 3.6mm 6mm 6mm 5mm 3.5mm 6mm 6mm
MD Max. 0.05mm 0.05mm 0.4mm 0.4mm 0.1mm 0.12mm 0.4mm 0.4mm
OP 38.2±0.8mm 49.7 ±1mm     45.8 ± 0.8mm 49.7 ±0.8mm   -

CZ-3 Compact Prewired Limit Switch

CZ-3 Compact Prewired Limit Switch
Specifications
  • DPDS limit switch for multiple applications
  • Rugged aluminum alloy diecast housing
  • High mechanical strength.
  • Oil resistance,waterproof and dustproof structur
Ratings
Rated Voltage (V) Noninductive Load (A) Inductive Load (A)
Resistance Load Lamp Load Inductive Load Motor Load
NC NO NC NO NC NO NC NO
125VAC
250VAC
5(0.1)
3
1.5
1
0.7
0.5
3
2
2
1.5
1.3
0.8
8VDC
14VDC
30VDC
125VDC
250VDC
5(0.1)
5(0.1)
4(0.1)
0.4
0.2
2
2
2
0.05
0.03
5
4
3
0.4
0.2
4
4
3
0.4
0.2
3
3
3
0.05
0.03
Characteristics

Rating
5A 125V, 3A 250VAC
Operating speed 1mm-1m/s
Operating frequency Mechanical: 120 operations/min.
Electrical: 30 operations/min.
Contact resistance 15mΩ max. (initial value)
Insulation resistance 100mΩ min. (at 500VDC)
Dielectric strength 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between currentcarrying
and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
Vibration frequency 10-55HZ,1.5mm double amplitude
Shock Mechanical: 1, 000m/Sec2 (about 100G'S)
Electrical: 500m/Sec2 (about 50G'S)
Ambient temperature -10℃ to +70℃
Humidity <95% RH
Life Mechanical: 10,000,000 operations min.
Electrical: 200,000 operations min.
Degree of protection IEC: IP 67
Weight Approx. 360g (cable length 3m)
Approx. 540g (cable length 5m)
Operating characteristics

Models
CZ-3101 CZ-3102 CZ-3103 CZ-3104 CZ-3110 CZ-3111 CZ-3112 CZ-3113 CZ-3169
OF Max. 1200gf
(11.77N)
1200g
f(11.77N)
1200gf
(11.77N)
580gf
(5.69N)
1200gf
(11.77N)
1800gf
(17.65N)
1800gf
(17.65N)
1800gf
(17.65N)
150gf
(1.47N)
RF Min. 450gf
(4.41N)
450gf
(4.41N)
450gf
(4.41N)
150gf
(1.47N)
450gf
(4.41N)
450gf
(4.41N)
450gf
(4.41N)
450gf
(4.41N)
-
PT Max. 1.8mm 1.8mm 1.8mm 25 1.8mm 1.8mm 1.8mm 1.8mm 15 º
OT Min. 3mm 3mm 3mm 40 3mm 3mm 3mm 3mm -
MD Max. 0.2mm 0.2mm 0.2mm 3 0.2mm 0.2mm 0.2mm 0.2mm -
OP 15.7 ± 1mm 28.5 ±1mm 28.5 ±1mm - 28.5± 1mm 24.9 ±1mm 34.3 ±1mm 34.3 ±1mm -
Fastening of the switch cable
The switch bodies are filled with resin for sealing purposes. To avoid stressing the cable and switch body, fasten the switch at 5 cm or farther away from the switch body, should the wire be bent, the bending radius shall be at least 45mm.
Installation
The service life and accuracy of switches will be effected bythe shape of actuator operation frequency & over travel. So theangular of the fixing level should be about 30, the surface finishof the fixing level should be over, the hardness is from HV400~500.When installing, the position of the concave part should be abovethe standard panel
Contact types Switch bank mounting
A maximum of six switches may be mounted together as a switch bank.During the installation,the convex part of the switch back.The mounting panel shall be 6mm or thicker.
Mounting
Recommended tightening torque according to the follwing form.
Mounting holes
Mount the switch body to a rigid mounting panel using two M5 screws.
Model Screw type Torque
1 M5 fastening screws 43.4~52lb.in (50~60kgf.cm)
2 M3.5 installing screws 6.9~7.9lb.in (8~9kgf.cm)

CZ-93 Safety Key Interlock Switch

CZ-93 Safety Key Interlock Switch
Model designations
Designation Signal Description
1. Type CZ-93 Safety switch
2. Type of contact blocks fitted B 2B (2NC)
C 1A1B (NO-NC)
3. Conduit entries PG PG 13.5XP1.5
PT PT1/2X14UNC
4. Actuating keys None None
01 Horizontal
02 Vertical
03 Adjustable
Ratings
Rated Voltage (V) Noninductive Load (A) Inductive Load (A)
Resistance Load Lamp Load Inductive Load Motor Load
NC NO NC NO NC NO NC NO
125VAC
250VAC
400VAC
10
10
10
3
2
1.5
1.5
1
0.8
10
10
3
5
3
1.5
2.5
1.5
0.8
8VDC
14VDC
30VDC
125VDC
250VDC
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
Characteristics
Rating 3A 240VAC (A300)
Operating speed 0.1m-0.5m/s
Operating frequency 30 operations/minute
Contact resistance 25mΩ max. (initial value)
Insulation resistance 100mΩ min. (at 500VDC)
Rated insulation voltage (UI) 400V
Dielectric strength AC2500V/Umip 4KV
Vibration frequency 10-55HZ,1.5mm double amplitude
Shock Mechanical: Approx. 1, 000m/Sec2 (about 100G'S)
Electrical: Approx. 300m/Sec2 (about 30G'S)
Ambient temperature -30℃ to +70℃
Humidity <95% RH
Life Mechanical: 10,000,000 operations above
Electrical: 150,000 operations above
Degree of protection IP65 (EN60947-5-1)
Short-circuit protective device 10A fuse
Weight Approx. 76g
Use attention affair
To prevent the wear and the space should be within 1mm between the key and middle of the insert hole.
When in use,there should put a plate on the top to prevent the key overinsert.To prevent nonmovement ,the space between the plate and the switch should be under 3 mm.

Required to have positive machine

When the contact block get fire,press on the middle of the key structure, the NC strict leaving structure can push the contact block a way cut off the movement.
SunShine Electric. Co.,LTD. TEL: 86-577-62737672 Mobile: 86-13706605914 FAX: 86-577-62737671 E-Mail: sunshine@sunshinele.com